KYORITSU KEW6201A Portable Appliance Testers

Product Details

The KEW 6201A is a portable appliance tester, performing four functions to ensure the Safety of ClassI and ClassII appliances. And also can measure the mains voltage.
Readings are displayed on a large liquid crystal display (LCD) below which are four LEDs which unambiguously display a pass or fail indication for threshold values dictated by AS/NZS 3760.

This instrument is suitable for performing tests as required by the following standards.
AS/NZS 3760 In-service safety inspection and testing of electrical equipment.


KYORITSU KEW 6205 Portable Appliance Testers

Product Details

Protect life and property from faulty appliances
・Battery operated
・PASS / FAIL result
・Color status back light
・10 mA & 30 mA RCD test(Isolation transformer built in)
¡¡Memory function up to 999 data
・Printer output
・Complies to AS / NZS 3760

KYORITSU KEW 4140 LOOP/PFC/PSC Testers

Product Details

• Anti-Trip Technology for complete trip free Loop testing on all RCDs rated 30mA and above.
• Dual Display allows simultaneous measurements like Loop & PFC/PSC.
• Two wire connection for Loop L-L, L-N and PSC testing is possible.
• Phase rotation, Voltage and Frequency measurements.
• Lock-down test button for 'hands free' testing with auto-start operation.
• Display and front panel keyboards with Backlight to be visible in dark places.
• Water and Dust proof (IP54)

KYORITSU 4118A LOOP/PFC/PSC Testers

Product Details

• Custom microprocessor controlled for highest accuracy and reliability.
• 3 LEDs for checking correct wiring status.
• 15mA LOOP measurement:
LOOP impedance 2000Ω range measurement is carried out with low test current (15mA).
The current will not cause tripping out involved RCD even the one with the lowest nominal differential current (30mA).
• Direct reading of Prospective Short Circuit Current (PSC).
• Safe voltage measurement function.
• Large custom digital display readout on all models.
• Measure low loop resistances(resolution of 0.01Ω)
• Automatic lock-out if test resister overheats.
• Large custom digital display readout .
• Visual indication of reversed phase and neutral wiring at socket.
• Designed to IP54 Rating
• Complies with IEC 61557

KYORITSU KEW 5410 RCD Testers

Product Details

• Measurement of RCD trip time
 Conducting testing of rated residual non-operating currents at
 × 1/2 Range, measuring RCD trip time at × 1 and × 5 Ranges.
• Measurement of trip out current
 Measuring trip out current by varying current automatically.
• Remote Test
 Enabling a user to hold the Test Leads with his both hands
 by locking the Test Button. Measurement will automatically
 start when the main voltage is detected.
• Voltage Measurement
 Carrying out a constant measurement of voltage in the
 stand-by mode at each Range.
• Auto-detection of Contact voltage
 Detecting the voltage to earth of Earth electrodes or
 Protective conductors during RCD test - when applying
 test currents - at measurement using EARTH in order to
 prevent electrical shocks caused by the damaged earth.
 Measurement will be ceased at AC50V or more.
• Dust- and Water-proof
 Dust- and Water-proof construction
 (designed to IEC 60529 IP54).
• Backlight
 Facilitating working at dimly illuminated locations.

KYORITSU 5406A RCD Testers

Product Details

• Custom microprocessor controlled for highest accuracy and reliability.
• 3 LEDs for checking correct wiring status.
• 0 and 180 degree phase angle switch permits quick tests and consistent readings.
• Digital read-out of tripping time.
• Constant current source circuitry ensures that a fluctuating mains voltage does not affect the accuracy of readings.
• Large custom digital display readout.
• Visual indication of reversed phase and neutral wiring at socket.
• Designed to IP54 Rating.
• Complies with IEC 61557
• Test of a large kind of RCD's: Standard, Selective, AC and A (DC sensitive breakers)
  