DEGSON DG042-5.08 PCB UNIVERSAL SCREW TERMINAL BLOCK

Item Data
APPROVAL /
Test standard /
Pitch                                              [mm] 5.08
Poles 02-03P
Rated torque                                      [N·m] /
Ambient temperature                               [¡æ] /
Relative humidity 5%-95%
Inspection standard MIL-STD-105E   II
AQL 0.65
Warranty 12   months
Material and plating Copper   alloy, Sn Plated

DEGSON DG127-THR-5.0-80A PCB UNIVERSAL SCREW TERMINAL BLOCK

Item Data    
APPROVAL  /    
Test standard IEC60947/   UL1059    
Pitch                                              [mm] 5    
Poles 02~24P    
IEC60947 Test data  IEC60947    
Rated voltage                                       [V] 320    
Rated current                                       [A] 13.5    
Rated connection   capacity)(solid/stranded)            [mm²] 0.2~1.5    
Surge voltage category/pollution degree/material group III/2/III    
Rated impulse voltage                               [KV] 4    
Rated torque                                      [N·m] Poles=2P    0.34N·m,    
    Poles≥3P  0.5N·m    
UL1059Test data UL 1059    
Use group B C D
Rated voltage                                       [V] 300   300
Rated   current                                       [A] 10   10
Rated connection capacity) (solid/stranded)           [AWG] 30~14    
Rated torque                                      [Lb. in] Poles=2P    3.04Lb.in    
  Poles≥3P  4.43Lb.in    
General data /    
Screw M3    
Inflammability class                                UL94 V-0    
Ambient temperature                               [¡æ] -40~+130    
Relative humidity 5%-95%    
Inspection standard MIL-STD-105E   II    
AQL 0.65    
Warranty 12   months    
Material and plating /    
Housing LCP    
Screws Steel   ,Zn Plated    
Contact Copper   alloy£¬Sn plated    
Cage Copper   alloy£¬Ni plated    
Wire connecting      
Recommended stripping length 6mm;      
1.£© For   solid wire, stripping wire to the appointed length, then tightening with   rated torque.    
2.£© For   stranded wire: stripping wire to the appointed length, mating with corresponding   type of ferrule, then tightening with rated torque.
Tightening process should be steady, can’t   use explosive force.

DEGSON DG381-THR-3.5/3.81 PCB UNIVERSAL SCREW TERMINAL BLOCK

Item Data    
APPROVAL      
Test standard IEC60947-7-4/UL1059    
Pitch                                     [mm] 3.50/3.81    
Poles 02-24P    
IEC60947-7-4 Test data /    
Rated voltage                              [V] 200    
Rated current                              [A] 13.5    
Rated connection capacity(solid/stranded) [mm2] 0.2-1.5    
Surge voltage category/pollution degree/material group III/2/I    
Rated impulse voltage                 [KV] 2.5    
Rated torque                              [N.m] 0.2    
UL1059Test data UL File Number E228872    
Use group B C D
Rated voltage                              [V] 150 / /
Rated current                              [A] 10 / /
Rated connection capacity (solid/stranded) [AWG] 26-16    
Rated torque                    [Lb. in] 1.77    
General data /    
Screw /    
Inflammability classUL94 V-0    
Ambient temperature                        [¡æ] -40~+130    
Relative humidity 5%-95%    
Inspection standard MIL-STD-105E II    
AQL 0.65    
Warranty 12 months    
Material and plating /    
Housing PA66    
Screws Steel£¬Zn plated    
Contact Copper alloy£¬Sn plated    
Cage Copper alloy£¬Ni plated    
Wire connecting      
Recommended stripping length 5-6mm;      
For solid wire,  stripping wire to the appointed length £¬press button and insert the wire.  
For stranded wire: stripping wire to the appointed length, mating with corresponding type of ferrule, then tightening with rated torque.
Tightening process should be steady, can’t use explosive force.

DEGSON DG636LF-7.5 PCB UNIVERSAL SCREW TERMINAL BLOCK

Item Data    
APPROVAL /    
Test standard IEC60947-7-4   / UL1059    
Pitch)                                              [mm] 7.5    
Poles 03P    
IEC60947-7-4 Test data    IEC60947-7-4    
Rated voltage                                          [V] 630    
Rated current                                          [A] 24    
Rated connection capacity(solid/stranded)              [mm²] 0.2~2.5    
Surge voltage category/pollution degree/material group ¢ó/2/¢ñ    
Rated impulse voltage                                 [KV] 6    
Rated torque)                                        [N·m] 0.6    
UL1059Test data UL 1059    
Use group B C C
Rated voltage)                                         [V] 300 / /
Rated   current                                        [A] 20 / /
Rated connection capacity (solid/stranded)            [AWG] 30-Dec    
Rated torqu                                         [Lb.   in] 5.32    
General data /    
Screw M3    
Inflammability class UL94 V-0    
Ambient temperature                                 [¡æ] -40~+105    
Relative humidity 5%-95%    
Inspection standard MIL-STD-105E   II    
AQL 0.65    
Warranty 12   months    
Material and plating /    
Housing PA66    
Screws Steel£¬Zn plated    
Contact Copper alloy£¬Sn plated    
Cage Copper   alloy£¬Ni plated    
Wire connecting      
 Recommended   stripping length 8mm;      
1.£©For solid   wire, stripping wire to the appointed length, then tightening with rated torque.  
2.£©For stranded   wire: stripping wire to the appointed length, mating with corresponding type   of ferrule, then tightening with rated torque.
Tightening process should be steady, can’t   use explosive force.

DEGSON DG636RF-7.5 PCB UNIVERSAL SCREW TERMINAL BLOCK

 Item Data    
APPROVAL /    
Test standard IEC60947-7-4   / UL1059    
Pitch)                                              [mm] 7.5    
Poles 03P    
IEC60947-7-4 Test data    IEC60947-7-4    
Rated voltage                                          [V] 630    
Rated current                                          [A] 24    
Rated connection capacity(solid/stranded)              [mm²] 0.2~2.5    
Surge voltage category/pollution degree/material group III/2/I    
Rated impulse voltage                                 [KV] 6    
Rated torque)                                      [N·m] 0.6    
UL1059Test data UL 1059    
Use group B C C
Rated voltage)                                         [V] 300 / /
Rated   current                                        [A] 20 / /
Rated connection capacity (solid/stranded)            [AWG] 30-Dec    
Rated torqu                                         [Lb.   in] 5.32    
General data /    
Screw M3    
Inflammability class UL94 V-0    
Ambient temperature                                 [¡æ] -40~+105    
Relative humidity 5%-95%    
Inspection standard MIL-STD-105E   II    
AQL 0.65    
Warranty 12   months    
Material and plating /    
Housing PA66    
Screws Steel£¬Zn plated    
Contact Copper alloy£¬Sn plated    
Cage Copper   alloy£¬Ni plated    
Wire connecting      
 Recommended   stripping length 8mm;      
1.£©For solid   wire, stripping wire to the appointed length, then tightening with rated torque.  
2.£©For stranded   wire: stripping wire to the appointed length, mating with corresponding type   of ferrule, then tightening with rated torque.
Tightening process should be steady, can’t   use explosive force.

DEGSON PS10-PE-10A PCB UNIVERSAL SCREW TERMINAL BLOCK

Item Data    
APPROVAL      
Test standard IEC60998-1   / UL1059    
Pitch                                     [mm] 10.00    
Poles 01-XXP    
IEC60998 Test data    /    
Rated voltage                              [V] /    
Rated current                              [A] /    
Rated connection capacity  solid/stranded  [mm2] 0.2~10    
Surge voltage category/pollution degree/material group III/2/I    
Withstanding Voltage                     [KV/min] /    
Rated torque                               [N·m] 1.2N·   m    
UL1059Test data UL   File Number E228872    
Use group B C D
Rated voltage)                              [V] / / /
Rated current                             [A] / / /
Rated connection capacity  solid/stranded [AWG] 44371.00    
Rated torque                            [Lb. in] 10.60    
General data /    
Screw M4     
Inflammability classUL94 V-0    
Ambient temperature                       [¡æ] -40~+105    
Relative humidity 5%-95%    
Inspection standard MIL-STD-105E   II    
AQL 0.65    
Warranty 12   months    
Material and plating /    
Housing PA66    
Screws Copper   alloy£¬Ni plated    
Contact Copper alloy£¬Sn plated    
Cage Copper   alloy£¬Ni plated    
Wire connecting      
12mm; Recommended stripping length 12mm;      
1.£©For solid wire, stripping wire to the   appointed length, then tightening with rated torque.  
2.£©For stranded wire: stripping wire to the   appointed length, mating with corresponding type of ferrule, then tightening   with rated torque.
Tightening process should be steady, can’t   use explosive force.

DEGSON PS10-PE PCB UNIVERSAL SCREW TERMINAL BLOCK

Item Data    
APPROVAL      
Test standard IEC60998-1 / UL1059    
Pitch                                     [mm] 10    
Poles 01-XXP    
IEC60998 Test data /    
Rated voltage                              [V] /    
Rated current                             [A] /    
Rated connection capacity(solid/stranded) [mm2] 0.2~10    
Surge voltage category/pollution degree/material group III/2/I    
Withstanding Voltage                    [KV/min] /    
Rated torque                              [N·m] 1.2N· m    
UL1059Test data UL File Number E228872    
Use group B C D
Rated voltage                             [V] / / /
Rated current                             [A] / / /
Rated connection capacity (solid/stranded) [AWG] 24-Jun    
Rated torque                            [Lb. in] 10.6    
General data /    
Screw M4      
Inflammability class UL94 V-0    
Ambient temperature                       [¡æ] -40~+105    
Relative humidity 5%-95%    
Inspection standard MIL-STD-105E II    
AQL 0.65    
Warranty 12 months    
Material and plating /    
Housing PA66    
Screws Copper alloy£¬Ni plated    
Contact Copper alloy£¬Sn plated    
Cage Copper alloy£¬Ni plated    
Wire connecting      
Recommended stripping length 12mm;      
For solid wire, stripping wire to the appointed length, then tightening with rated torque.    
For stranded wire: stripping wire to the appointed length, mating with corresponding type of ferrule, then tightening with rated torque.
Tightening process should be steady, can’t use explosive force.

DEGSON PS10-10A PCB UNIVERSAL SCREW TERMINAL BLOCK

Item Data    
APPROVAL      
Test standard IEC60998-1:2004   / UL1059    
Pitch                                    [mm] 10    
Poles 01-XXP    
IEC60998 Test data    /    
Rated voltage                              [V] 450    
Rated current                              [A] 57    
Rated connection capacity solid/stranded)  [mm2] 0.2~10    
Surge voltage category/pollution degree/material group III/2/I    
Withstanding Voltage                    [KV/min] 2.5    
Rated torque                              [N·m] 1.2    
UL1059Test data UL   File Number E228872    
Use group) B C D
Rated voltage                             [V] 600 600 600
Rated current                             [A] 70 70 5
(Rated connection capacity) (solid/stranded) [AWG] 24-Jun    
Rated torque                            [Lb. in] 10.5    
General data -    
Screw M4     
nflammability classUL94 V-0    
Ambient temperature                        [¡æ] -40~+105    
Relative humidity 5%-95%    
Inspection standard£© MIL-STD-105E   II    
AQL 0.65    
Warranty 12   months    
Material and plating /    
Housing PA66    
Screws Copper   alloy£¬Ni plated    
Contact  Copper alloy£¬ Sn plated    
Cage Copper   alloy£¬Ni plated    
Wire connecting      
12mm; Recommended stripping length 12mm;      
1.For solid wire, stripping wire to the appointed   length, then tightening with rated torque.    
2.£©For stranded wire: stripping wire to the   appointed length, mating with corresponding type of ferrule, then tightening   with rated torque.
Tightening process should be steady, can’t   use explosive force.

DEGSON DG107V-7.62 PCB UNIVERSAL SCREW TERMINAL BLOCK

Item Data    
APPROVAL /    
Test standard IEC60947-7-4/UL1059    
Pitch                                    [mm] 7.62    
Poles 02-XXP    
IEC60947-7-4 Test   data /    
Rated voltage                             [V] 630    
Rated current                             [A] 32    
Rated connection   capacity)(solid/stranded  [mm2] 0.5-6.0    
Surge   voltage category/pollution degree/material group III/2/I    
Rated impulse voltage                  [KV] 6    
Rated torque)                               [N.m] 0.5    
UL1059Test data) UL1059    
Use group) B C D
Rated voltage)                             [V] 300 / /
Rated current                             [A] 30 / /
Rated connection   capacity) (solid/stranded [AWG] 26-Oct    
Rated torque£©                              [Lb. in] 4.43    
General data) /    
Screw) M3    
Inflammability   class)UL94 V-0    
Ambient   temperature)                        [¡æ] -40~+105    
Relative humidity) 5%-95%    
Inspection standard£© MIL-STD-105E   II    
AQL) 0.65    
Warranty) 12   months    
Material and plating£© /    
Housing) PA66    
Screws) Steel£¬Zn plated    
Contact) Copper   alloy£¬Sn plated    
Cage) Steel£¬Zn plated    
Wire connecting      
13-14mm; Recommended stripping   length 13-14mm;      
1.£©For   solid wire,  stripping wire to the   appointed length £¬press button and insert the wire.  
2.£©For stranded   wire: stripping wire to the appointed length, mating with corresponding type   of ferrule, then tightening with rated torque.
Tightening   process should be steady, can’t use explosive force.)

DEGSON DG107R-7.62 PCB UNIVERSAL SCREW TERMINAL BLOCK

Item Data    
APPROVAL      
Test standard IEC60947-7-4/UL1059    
Pitch                                    [mm] 7.62    
Poles 01-XXP    
 IEC60947-7-4 Test   data)  /    
Rated voltage                             [V] 630    
Rated current                             [A] 32    
Rated connection   capacity  solid/stranded [mm2] 0.5-6    
Surge   voltage category/pollution degree/material group) III/2/I    
Rated impulse voltage                   [KV] 6    
Rated torque                              [N.m] 0.5    
UL1059Test data) UL1059    
Use group) B C D
Rated voltage)                              [V] 300 / 300
Rated current)                              [A] 30 / 10
Rated connection   capacity) (solid/stranded  [AWG] 26-Oct    
Rated torque                              [Lb. in] 4.43    
General data) /    
Screw M3    
Inflammability   class)UL94 V-0    
Ambient   temperature                      [¡æ] -40~+105    
Relative humidity 5%-95%    
Inspection standard£© MIL-STD-105E   II    
AQL) 0.65    
Warranty 12   months    
Material and plating /    
Housing PA66    
Screws Steel£¬Zn plated    
Contact Copper   alloy£¬Sn plated    
Cage Steel£¬Zn plated    
Wire connecting      
13-14mm; Recommended stripping   length 13-14mm;      
1.£©For   solid wire,  stripping wire to the   appointed length £¬press button and insert the wire.  
2.£©For stranded   wire: stripping wire to the appointed length, mating with corresponding type   of ferrule, then tightening with rated torque.
Tightening   process should be steady, can’t use explosive force.)

DEGSON DG107R-6.35 PCB UNIVERSAL SCREW TERMINAL BLOCK

Item Data    
APPROVAL      
Test standard IEC60947-7-4/UL1059    
Pitch                                      [mm] 6.35    
Pole 01-XXP    
IEC60947-7-4 Test   data /    
Rated voltage                             [V] 320    
Rated current                            [A] 41    
Rated connection   capacity)(solid/stranded [mm2] 0.5-6    
Surge   voltage category/pollution degree/material group III/2/I    
Rated impulse voltage                   [KV] 4    
Rated torque                               [N.m] 0.5    
UL1059Test data UL1059    
Use group B C D
Rated voltage                             [V] 300 / 300
Rated current                              [A] 30 / 10
Rated connection   capacity solid/stranded  [AWG] 26-Oct    
Rated torque                              [Lb. in] 4.43    
General data /    
Screw M3    
Inflammability   classUL94 V-0    
Ambient   temperature                       [¡æ] -40~+105    
Relative humidity 5%-95%    
Inspection standard MIL-STD-105E   II    
AQL 0.65    
Warranty 12   months    
Material and plating /    
Housing PA66    
Screws Steel£¬Zn plated    
Contact Copper   alloy£¬Sn plated    
Cage Steel£¬Zn plated    
Wire connecting      
3-14mm; Recommended stripping   length 13-14mm;      
1.£©For   solid wire,  stripping wire to the   appointed length £¬press button and insert the wire.  
2.£©For stranded   wire: stripping wire to the appointed length, mating with corresponding type   of ferrule, then tightening with rated torque.
Tightening   process should be steady, can’t use explosive force.)    
 

DEGSON DG105V-7.5-10A PCB UNIVERSAL SCREW TERMINAL BLOCK

Item Data    
APPROVAL)        /    
Test standard) IEC60998-1/UL1059    
Pitch)                                      [mm] 7.5    
Poles) 02-XXP    
 IEC60998 Test data)  /    
Rated voltage)                              [V] 450    
Rated current)                              [A] 24    
Rated connection   capacity)(solid/stranded) [mm2] 0.5-2.5    
Surge   voltage category/pollution degree/material group) III/2/I    
Withstanding Voltage                    [KV/min] 2.5    
Rated torque                              [N.m] 0.4    
UL1059Test data UL   File Number E228872    
Use group B C D
Rated voltage                             [V] 300 / 300
Rated current                             [A] 20 / 10
Rated connection   capacity) (solid/stranded  [AWG] 30-Dec    
Rated torque£©                              [Lb. in] 3.54    
General data) /    
Screw) M2.5    
Inflammability   classUL94 V-0    
Ambient   temperature                        [¡æ] -40~+105    
Relative humidity 5%-95%    
Inspection standard MIL-STD-105E   II    
AQL 0.65    
Warranty 12   months    
Material and plating /    
Housing PA66    
Screws) Steel£¬Zn plated    
Contact Copper   alloy£¬Sn plated    
Cage Steel£¬Zn plated    
(Wire connecting)      
13-14mm; Recommended stripping   length 13-14mm;      
1.£©For   solid wire,  stripping wire to the   appointed length £¬press button and insert the wire.  
2.£©For stranded   wire: stripping wire to the appointed length, mating with corresponding type   of ferrule, then tightening with rated torque.
Tightening   process should be steady, can’t use explosive force.

DEGSON DG105V-5.0-10A PCB UNIVERSAL SCREW TERMINAL BLOCK

Item Data    
APPROVAL      
Test standard IEC/EN60998-1:2004/   UL1059    
Pitch                                     [mm] 5    
Poles 02-XXP    
EN60998 Test data VDE   certificate NO. 40024865    
Rated voltage                              [V] 250    
Rated current                              [A] 24    
Rated connection   capacity)(solid/stranded [mm2] 0.5-2.5    
Surge   voltage category/pollution degree/material group) III/2/I    
Withstanding Voltage                  [KV/min] 2    
Rated torque                              [N.m] 0.4    
UL1059Test data UL   File Number E228872    
Use group B C D
Rated voltage                              [V] 300 / 300
Rated current                             [A] 20 / 10
Rated connection   capacity) (solid/stranded [AWG] 30-Dec    
Rated torque                             [Lb. in] 4.4    
General data /    
Screw M2.5    
Inflammability   classUL94 V-0    
Ambient   temperature                       [¡æ] -40~+105    
Relative humidity 5%-95%    
Inspection standard MIL-STD-105E   II    
AQL 0.65    
Warranty 12   months    
Material and plating /    
Housing PA66    
Screws Steel£¬Zn plated    
Contact Copper   alloy£¬Sn plated    
Cage) Steel£¬Zn plated    
Wire connecting      
13-14mm; Recommended stripping   length 13-14mm;      
1.£©For   solid wire,  stripping wire to the   appointed length £¬press button and insert the wire.    
2.£©For stranded   wire: stripping wire to the appointed length, mating with corresponding type   of ferrule, then tightening with rated torque.
Tightening   process should be steady, can’t use explosive force.

DEGSON DG105V-7.5 PCB UNIVERSAL SCREW TERMINAL BLOCK

Item Data    
APPROVAL      
Test standard IEC60998-1£º2004 / UL1059    
Pitch                                     [mm] 7.5    
Poles 01-XXP    
IEC60998 Test data   -    
Rated voltage                             [V] 250    
Rated current                             [A] 24    
Rated connection   capacity)(solid/stranded  [mm2] 0.5-2.5    
Surge   voltage category/pollution degree/material group) III/2/I    
Withstanding  voltage                 [KV/min] 2    
Rated torque                             [N.m] 0.4    
UL1059Test data UL   File Number E228872    
Use group B C D
Rated voltage                             [V] 300 / 300
Rated current                            [A] 20 / 10
Rated connection   capacity) (solid/stranded [AWG] 30-Dec    
Rated torque                             [Lb. in] 3.54    
General data /    
Screw M2.5    
Inflammability   classUL94 V-0    
Ambient   temperature                      [¡æ] -40~+105    
Relative humidity 5%-95%    
Inspection standard MIL-STD-105E   II    
AQL 0.65    
Warranty 12   months    
Material and plating /    
Housing PA66    
Screws Steel£¬Ni plated    
Contact Copper alloy£¬Sn plated    
Block Steel£¬Zn plated    
Cage Steel£¬Zn plated    
Wire connecting      
12-13mm; Recommended stripping   length 12-13mm;      
1.£©For solid   wire, stripping wire to the appointed length, then tightening with rated torque.    
2.£©For stranded   wire: stripping wire to the appointed length, mating with corresponding type   of ferrule, then tightening with rated torque.
Tightening   process should be steady, can’t use explosive force.

DEGSON DG105V-5.0 PCB UNIVERSAL SCREW TERMINAL BLOCK

Item Data    
APPROVAL      
Test standard IEC/EN60998-1£º2004 / UL1059    
Pitch                               [mm] 5    
Poles 01-24P    
EN60998 Test data   VDE   certificate NO. 40024865    
Rated voltage                           [V] 250    
Rated current                            [A] 24    
Rated connection   capacity solid/stranded [mm2] 0.5-2.5    
Surge   voltage category/pollution degree/material group III/2/I    
Withstanding  voltage                  [KV/min] 2    
Rated torque                               [N.m] 0.4    
UL1059Test data UL   File Number E228872    
Use group B C D
Rated voltage                             [V] 300 / 300
Rated current                              [A] 20 / 10
Rated connection   capacity) (solid/stranded [AWG] 30-Dec    
Rated torque                              [Lb. in] 3.54    
General data /    
Screw M2.5    
Inflammability   classUL94 V-0    
Ambient   temperature                      [¡æ] -40~+105    
Relative humidity 5%-95%    
Inspection standard MIL-STD-105E   II    
AQL 0.65    
Warranty 12   months    
Material and plating /    
Housing PA66    
Screws Steel£¬Ni plated    
Contact Copper alloy£¬Sn plated    
Bloc Steel£¬Zn plated    
Cage Steel£¬Zn plated    
Wire connecting      
12-13mm; Recommended stripping   length 12-13mm;      
1.£©For solid   wire, stripping wire to the appointed length, then tightening with rated torque.    
2.£©For stranded   wire: stripping wire to the appointed length, mating with corresponding type   of ferrule, then tightening with rated torque.
 Tightening   process should be steady, can’t use explosive force.

DEGSON DG105R-7.5-10A PCB UNIVERSAL SCREW TERMINAL BLOCK

Item Data    
APPROVAL /    
Test standard IEC60998-1£º2004 / UL1059    
Pitch                                    [mm] 7.5    
Poles 01-24P    
IEC60998 Test data   -    
Rated voltage                            [V] 250    
Rated current                              [A] 24    
Rated connection   capacity solid/stranded  [mm2] 0.5-2.5    
Surge   voltage category/pollution degree/material group) III/2/I    
Withstanding  voltage                 [KV/min] 2    
Rated torque                              [N.m] 0.4    
UL1059Test data UL   File Number E228872    
Use group B C D
Rated voltag                              [V] 300 / 300
Rated current                            [A] 20 / 10
Rated connection   capacity Solid/stranded  [AWG] 30-Dec    
Rated torque                              [Lb. in] 3.54    
General data /    
Screw M2.5    
Inflammability   classUL94 V-0    
Ambient   temperature                    [¡æ] -40~+105    
Relative humidity 5%-95%    
Inspection standard MIL-STD-105E   II    
AQL 0.65    
Warranty 12   months    
Material and plating /    
Housing PA66    
ScrewS Steel£¬Ni plated    
Contact Copper alloy£¬Sn plated    
Block Steel£¬Zn plated    
Cage Steel£¬Zn plated    
Wire connecting      
12-13mm; Recommended stripping   length 12-13mm;      
1.£©For solid   wire, stripping wire to the appointed length, then tightening with rated torque.    
2.For stranded   wire: stripping wire to the appointed length, mating with corresponding type   of ferrule, then tightening with rated torque.
Tightening   process should be steady, can’t use explosive force.

DEGSON DG105R-5.0-10A PCB UNIVERSAL SCREW TERMINAL BLOCK

Item Data    
APPROVAL /    
Test standard IEC/EN60998-1£º2004 / UL1059    
Pitch                                     [mm] 5    
Poles 01-24P    
EN60998 Test data VDE   certificate NO. 40024865    
Rated voltage                             [V] 250    
Rated current                             [A] 24    
Rated connection   capacity  solid/stranded[mm2] 0.5-2.5    
Surge   voltage category/pollution degree/material group III/2/I    
Withstanding  voltage                  [KV/min] 2    
Rated torque                         [N.m] 0.4    
UL1059Test data UL   File Number E228872    
Use group B C D
Rated voltage                             [V] 300 / 300
Rated current                              [A] 20 / 10
Rated connection   capacity solid/stranded  [AWG] 30-Dec    
Rated torque                              [Lb. in] 3.54    
General data /    
Screw M2.5    
Inflammability   class UL94 V-0    
Ambient   temperature                       [¡æ] -40~+105    
Relative humidity 5%-95%    
Inspection standard MIL-STD-105E   II    
AQL 0.65    
Warranty 12   months    
Material and plating /    
Housing PA66    
Screws Steel£¬Ni plated    
Contact Copper alloy£¬Sn plated    
Block Steel£¬Zn plated    
Cage Steel£¬Zn plated    
Wire connecting      
2-13mm; Recommended stripping   length 12-13mm;      
1.£©For solid   wire, stripping wire to the appointed length, then tightening with rated torque.    
2.£©For stranded   wire: stripping wire to the appointed length, mating with corresponding type   of ferrule, then tightening with rated torque.
Tightening   process should be steady, can’t use explosive force.)

DEGSON DG105R-7.5 PCB UNIVERSAL SCREW TERMINAL BLOCK

Item Data    
APPROVAL      
Test standard IEC60998-1£º2004 / UL1059    
Pitch                                    [mm] 7.5    
Poles 01-24P    
IEC60998 Test data    -    
Rated voltage                             [V] 250    
Rated current                             [A] 24    
Rated connection   capacity  solid/stranded  [mm2] 0.5-2.5    
Surge   voltage category/pollution degree/material group III/2/I    
Withstanding  voltage                  [KV/min] 2    
Rated torque)                              [N.m] 0.4    
UL1059Test data UL   File Number E228872    
Use group B C D
Rated voltage                           [V] 300 / 300
Rated current                             [A] 20 / 10
Rated connection   capacity  solid/stranded  [AWG] 30-Dec    
Rated torqu                            [Lb. in] 3.54    
General data /    
Screw M2.5    
Inflammability   class)UL94 V-0    
Ambient   temperature                      [¡æ] -40~+105    
Relative humidity 5%-95%    
Inspection standard MIL-STD-105E   II    
AQL 0.65    
(Warranty 12   months    
Material and plating /    
(Housing PA66    
Screws Steel£¬Ni plated    
Contact Copper alloy£¬Sn plated    
Block Steel£¬Zn plated    
Cage Steel£¬Zn plated    
Wire connecting      
12-13mm; Recommended stripping   length 12-13mm;      
1.£©For solid   wire, stripping wire to the appointed length, then tightening with rated torque.  
2.£©For stranded   wire: stripping wire to the appointed length, mating with corresponding type   of ferrule, then tightening with rated torque.
Tightening   process should be steady, can’t use explosive force.

DEGSON DG128-5.08 SCREW TYPE PCB TERMINAL BLOCK

DG128-5.08-1000A(H)-10040004033

PCB terminal blocks£¬Rated current : 18A£¬Rated voltage £šIII/2£©400V£¬Cross section£º0.2-2.5mm²£¬Pitch£º5.08mm£¬Screw connection with tension sleeve£¬Color£ºgreen£¬Contact surface £ºTin

DEGSON DG127-THR-5.0 SCREW TYPE PCB TERMINAL BLOCK

DG127-THR-5.0-10040003968

PCB terminal blocks£¬Rated current : 13.5A£¬Rated voltage £šIII/2£©320V£¬Cross section£º0.2-1.5mm²£¬Pitch£º5.0mm£¬Screw connection with tension sleeve£¬Color£ºblack£¬Contact surface £ºTin

DEGSON DSMT2.5-5.08 SCREW TYPE PCB TERMINAL BLOCK

DSMT2.5-5.08-10040002269

PCB terminal blocks£¬Rated current : 15A£¬Rated voltage £šIII/2£©320V£¬Cross section£º0.2-2.5mm²£¬Pitch£º5.08mm£¬Screw connection with tension sleeve£¬Color£ºgreen£¬Contact surface £ºTin

DEGSON PS4-7.5 SCREW TYPE PCB TERMINAL BLOCK

PS4-7.5-10040002266

PCB terminal blocks£¬Rated current : 32£¬Rated voltage £šIII/2£©320V£¬Cross section£º0.2-4.0mm²£¬Pitch£º7.5mm£¬Screw connection with tension sleeve£¬Color£ºgreen£¬Contact surface £ºTin

DEGSON PS10 SCREW TYPE PCB TERMINAL BLOCK

PS10-10040002264

PCB terminal blocks£¬Rated current : 57A£¬Rated voltage £šIII/2£©450V£¬Cross section£º0.2-10mm²£¬Pitch£º10.0mm£¬Screw connection with tension sleeve£¬Color£ºgreen£¬Contact surface £ºTin

DEGSON DG381-THR-3.81 SCREW TYPE PCB TERMINAL BLOCK

DG381-THR-3.81-10040002116

PCB terminal blocks£¬Rated current : 13.5A£¬Rated voltage £šIII/2£©200V£¬Cross section£º0.2-1.5mm²£¬Pitch£º3.81mm£¬Screw connection with tension sleeve£¬Color£ºblack£¬Contact surface £ºTin