DEGSON - DQ-012-FC

Item Data
Inserts MatchingD3A Hoods&Housings
APPROVAL UL.CSA.VDE.CE.CQC
Test standard DIN EN61 984 / UL1977
Poles 12P+PE
The need for additional or dering crimp contacts Yes, 10A contacts
EN61984 Test data /
Rated voltage                                   [V] 400
Rated current                                   [A] 10
pollution degree 3
Rated impulse voltage                           [KV] 6
Insulation resistance ≥1010Ω
UL/CSARated current               ¡¡¡¡¡¡¡¡¡¡  [V] 600
Material Polycarbonate
Inflammability class(UL94) V-0
Ambient temperature                            [¡æ] -40~+125
Mechanical working life(mating cycles) ≥500
Contacts
Material Copper alloy
Surface Hard-silver plated
Hard-gold plated
Contact resistance ≤3mΩ
Terminal Crimp terminal
Rated connection capacity(solid/stranded) 0.14—2.5mm² (AWG26-14)
Recommended stripping length 7.5mm

DEGSON - DQ-012-MC

Item Data
Inserts MatchingD3A Hoods&Housings
APPROVAL UL.CSA.VDE.CE.CQC
Test standard DIN EN61 984 / UL1977
Poles 12P+PE
The need for additional or dering crimp contacts Yes, 10A contacts
EN61984 Test data /
Rated voltage                                   [V] 400
Rated current                                   [A] 10
pollution degree 3
Rated impulse voltage                           [KV] 6
Insulation resistance ≥1010Ω
UL/CSARated current               ¡¡¡¡¡¡¡¡¡¡  [V] 600
Material Polycarbonate
Inflammability class(UL94) V-0
Ambient temperature                            [¡æ] -40~+125
Mechanical working life(mating cycles) ≥500
Contacts  
Material Copper alloy
Surface Hard-silver plated
  Hard-gold plated
Contact resistance ≤3mΩ
Terminal Crimp terminal
Rated connection capacity(solid/stranded) 0.14—2.5mm² (AWG26-14)
Recommended stripping length 7.5mm  
 

DEGSON - DQ-007-FC

 Item Data
Inserts MatchingD3A Hoods&Housings
APPROVAL UL.CSA.VDE.CE.CQC
Test standard DIN EN61 984 / UL1977
Poles 7P+PE
The need for additional or dering crimp contacts Yes, 10A contacts
EN61984 Test data   /
Rated voltage                                   [V] 400
Rated current                                   [A] 10
pollution degree 3
Rated impulse voltage                           [KV] 6
Insulation resistance ≥1010Ω
UL/CSARated current               ¡¡¡¡¡¡¡¡¡¡  [V] 600
Material Polycarbonate
Inflammability class(UL94) V-0
Ambient temperature                            [¡æ] -40~+125
Mechanical working life(mating cycles) ≥500
Contacts  
Material Copper alloy
Surface Hard-silver plated
  Hard-gold plated
Contact resistance ≤3mΩ
Terminal Crimp terminal
Rated connection capacity(solid/stranded) 0.14—2.5mm² (AWG26-14)
Recommended stripping length 7.5mm  
 

DEGSON - DQ-007-MC

 Item Data
Inserts MatchingD3A Hoods&Housings
APPROVAL UL.CSA.VDE.CE.CQC
Test standard DIN EN61 984 / UL1977
Poles 7P+PE
The need for additional or dering crimp contacts Yes, 10A contacts
EN61984 Test data   /
Rated voltage                                   [V] 400
Rated current                                   [A] 10
pollution degree 3
Rated impulse voltage                           [KV] 6
Insulation resistance ≥1010Ω
UL/CSARated current               ¡¡¡¡¡¡¡¡¡¡  [V] 600
Material Polycarbonate
Inflammability class(UL94) V-0
Ambient temperature                            [¡æ] -40~+125
Mechanical working life(mating cycles) ≥500
Contacts
Material Copper alloy
Surface Hard-silver plated
Hard-gold plated
Contact resistance ≤3mΩ
Terminal Crimp terminal
Rated connection capacity(solid/stranded) 0.14—2.5mm² (AWG26-14)
Recommended stripping length 7.5mm

 

DEGSON - DQ-005-FC

Item Data
Inserts MatchingD3A Hoods&Housings
APPROVAL UL.CSA.VDE.CE.CQC
Test standard DIN EN61 984 / UL1977
Poles 5P+PE
The need for additional or dering crimp contacts Yes, 16A contacts
EN61984 Test data /
Rated voltage                                   [V] 400
Rated current                                   [A] 16
pollution degree 3
Rated impulse voltage                           [KV] 4
Insulation resistance ≥1010Ω
UL/CSARated current ¡¡¡¡¡¡¡¡¡¡                [V] 600
Material Polycarbonate
Inflammability class(UL94) V-0
Ambient temperature                       [¡æ] -40~+125
Mechanical working life(mating cycles) ≥500
Contacts
Material Copper alloy
Surface Hard-silver plated
Hard-gold plated
Contact resistance ≤1mΩ
Terminal Crimp terminal
Rated connection capacity(solid/stranded) 0.14—2.5mm² (AWG26-14)
Recommended stripping length 7.5mm

DEGSON - DQ-005-MC

Item Data
Inserts MatchingD3A Hoods&Housings
APPROVAL UL.CSA.VDE.CE.CQC
Test standard DIN EN61 984 / UL1977
Poles 5P+PE
The need for additional or dering crimp contacts Yes, 16A contacts
EN61984 Test data /
Rated voltage                                   [V] 400
Rated current                                   [A] 16
pollution degree 3
Rated impulse voltage                           [KV] 4
Insulation resistance ≥1010Ω
UL/CSARated current ¡¡¡¡¡¡¡¡¡¡                [V] 600
Material Polycarbonate
Inflammability class(UL94) V-0
Ambient temperature                       [¡æ] -40~+125
Mechanical working life(mating cycles) ≥500
Contacts  
Material Copper alloy
Surface Hard-silver plated
  Hard-gold plated
Contact resistance ≤1mΩ
Terminal Crimp terminal
Rated connection capacity(solid/stranded) 0.14—2.5mm² (AWG26-14)
Recommended stripping length 7.5mm  
 

DEGSON - DK-8/0-F

Item Data
Inserts MatchingD24B Hoods&Housings
APPROVAL UL.CSA.VDE.CE.CQC
Test standard DIN EN61 984 / UL1977
Poles 8/0P+PE
The need for additional or dering crimp contacts No
EN61984 Test data  
Rated voltage                                    [V] 690
Rated current                                    [A] 100
pollution degree 3
Rated impulse voltage                            [KV] 8
Insulation resistance ≥1010Ω
UL/CSARated current ¡¡¡¡¡¡¡¡¡¡                  [V] 600
Material Polycarbonate
Inflammability class(UL94) V-0
Ambient temperature                             [¡æ] -40~+125
Mechanical working life(mating cycles) ≥500
Contacts
Material Copper alloy
Surface Hard-silver plated
Contact resistance ≤0.5mΩ
Terminal Axial Screw terminal
terminal tightening      10    16    25         £¨ mm²£©
 6     6     7            [N·m]  
Rated connection capacity(solid/stranded) 10-25mm²  (AWG7-3)
Wire connecting
Recommended stripping length13mm;
For stranded wire: stripping wire to the appointed length, then tightening with rated torque.
Tightening process should be steady, can’t use explosive force.
 

DEGSON - DK-4/2-F

Item Data
Inserts MatchingD16B Hoods&Housings
APPROVAL UL.CSA.VDE.CE.CQC
Test standard DIN EN61 984 / UL1977
Poles 4/2P+PE
The need for additional or dering crimp contacts No
EN61984 Test data /
Rated voltage                                     [V] 690/400
Rated current                                     [A] 80/16
pollution degree 3
Rated impulse voltage                             [KV] 8-Jun
Insulation resistance ≥1010Ω
UL/CSARated current                  ¡¡¡¡¡¡¡¡¡¡  [V] 600/300
Material Polycarbonate
nflammability class(UL94) V-0
Ambient temperature                              [¡æ] -40~+125
Mechanical working life(mating cycles) ≥500
Contacts
Material Copper alloy
Surface Hard-silver plated
Contact resistance Power area ≤0.3mΩ
Signal area ≤1mΩ
Terminal Screw terminal
Power  area  Screw terminal tightening       1.5   2.5   4   6   10   16£¨ mm²£©
1.2   2     3   3    3    3   [N·m]  
Signal ¡¡area  Screw terminal tightening 0.5                           [N·m]
Power¡¡area¡¡connection capacity(solid/stranded) 1.5-16mm²  (AWG16-6)
Signal  area¡¡connection capacity(solid/stranded) 0.5-2.5mm² (AWG20-14)
Screw M6/M3, (Steel£¬Ni plated )
Wire connecting
Recommended stripping length/Power area14mm/Signal area 7.5mm
For solid wire, stripping wire to the appointed length, then tightening with rated torque.
For stranded wire: stripping wire to the appointed length, mating with corresponding type of ferrule, then tightening with rated torque.
Tightening process should be steady, can’t use explosive force.
 

DEGSON - DK-4/8-F

Item Data
Inserts MatchingD24B Hoods&Housings
APPROVAL UL.CSA.VDE.CE.CQC
Test standard DIN EN61 984 / UL1977
Poles 4/8P+PE
The need for additional or dering crimp contacts) ·ñ
  No
EN61984 Test data /
Rated voltage                                      [V] 400/400
Rated current                                      [A] 80/16
pollution degree 3
Rated impulse voltage                              [KV] 6-Jun
Insulation resistance ≥1010Ω
UL/CSARated current ¡¡¡¡¡¡¡¡¡¡                   [V] 600/600
Material Polycarbonate
Inflammability class(UL94) V-0
Ambient temperature                               [¡æ] -40~+125
Mechanical working life(mating cycles) ≥500
Contacts  
Material Copper alloy
Surface Hard-silver plated
Contact resistance Power area ≤0.3mΩ
  Signal area ≤1mΩ
Terminal Screw terminal
Power  area  Screw terminal tightening       1.5   2.5   4   6   10   16£¨ mm²£©
  1.2   2     3   3    3    3   [N·m]  
Signal ¡¡area  Screw terminal tightening 0.5                           [N·m]
Power¡¡area¡¡connection capacity(solid/stranded) 1.5-16mm²  (AWG16-6)
Signal  area¡¡connection capacity(solid/stranded) 0.5-2.5mm² (AWG20-14)
Screw M6/M3, (Steel£¬Ni plated )
Wire connecting  
Recommended stripping length/Power area14mm/Signal area 7.5mm
For solid wire, stripping wire to the appointed length, then tightening with rated torque.
For stranded wire: stripping wire to the appointed length, mating with corresponding type of ferrule, then tightening with rated torque.
Tightening process should be steady, can’t use explosive force.

DEGSON - DK-8/0-M

Item Data
Inserts MatchingD24B Hoods&Housings
APPROVAL UL.CSA.VDE.CE.CQC
Test standard DIN EN61 984 / UL1977
Poles 8/0P+PE
The need for additional or dering crimp contacts No
EN61984 Test data  
Rated voltage                                    [V] 690
Rated current                                    [A] 100
pollution degree 3
Rated impulse voltage                            [KV] 8
Insulation resistance ≥1010Ω
UL/CSARated current ¡¡¡¡¡¡¡¡¡¡                  [V] 600
Material Polycarbonate
Inflammability class(UL94) V-0
Ambient temperature                             [¡æ] -40~+125
Mechanical working life(mating cycles) ≥500
Contacts
Material Copper alloy
Surface Hard-silver plated
Contact resistance ≤0.5mΩ
Terminal Axial Screw terminal
terminal tightening      10    16    25         £¨ mm²£©
 6     6     7            [N·m]  
Rated connection capacity(solid/stranded) 10-25mm²  (AWG7-3)
Wire connecting
Recommended stripping length13mm;
For stranded wire: stripping wire to the appointed length, then tightening with rated torque.
Tightening process should be steady, can’t use explosive force.

DEGSON - DK-4/2-M

Item Data
Inserts MatchingD16B Hoods&Housings
APPROVAL UL.CSA.VDE.CE.CQC
Test standard DIN EN61 984 / UL1977
Poles 4/2P+PE
The need for additional or dering crimp contacts No
EN61984 Test data /
Rated voltage                                     [V] 690/400
Rated current                                     [A] 80/16
pollution degree 3
Rated impulse voltage                             [KV] 8-Jun
Insulation resistance ≥1010Ω
UL/CSARated current                  ¡¡¡¡¡¡¡¡¡¡  [V] 600/300
Material Polycarbonate
nflammability class(UL94) V-0
Ambient temperature                              [¡æ] -40~+125
Mechanical working life(mating cycles) ≥500
Contacts
Material Copper alloy
Surface Hard-silver plated
Contact resistance Power area ≤0.3mΩ
Signal area ≤1mΩ
Terminal Screw terminal
Power  area  Screw terminal tightening       1.5   2.5   4   6   10   16£¨ mm²£©
1.2   2     3   3    3    3   [N·m]  
Signal ¡¡area  Screw terminal tightening 0.5                           [N·m]
Power¡¡area¡¡connection capacity(solid/stranded) 1.5-16mm²  (AWG16-6)
Signal  area¡¡connection capacity(solid/stranded) 0.5-2.5mm² (AWG20-14)
Screw M6/M3, (Steel£¬Ni plated )
Wire connecting
Recommended stripping length/Power area14mm/Signal area 7.5mm
For solid wire, stripping wire to the appointed length, then tightening with rated torque.
For stranded wire: stripping wire to the appointed length, mating with corresponding type of ferrule, then tightening with rated torque.
Tightening process should be steady, can’t use explosive force.

DEGSON - DK-4/8-M

Item Data
Inserts MatchingD24B Hoods&Housings
APPROVAL UL.CSA.VDE.CE.CQC
Test standard DIN EN61 984 / UL1977
Poles 4/8P+PE
The need for additional or dering crimp contacts) ·ñ
  No
EN61984 Test data /
Rated voltage                                      [V] 400/400
Rated current                                      [A] 80/16
pollution degree 3
Rated impulse voltage                              [KV] 6-Jun
Insulation resistance ≥1010Ω
UL/CSARated current ¡¡¡¡¡¡¡¡¡¡                   [V] 600/600
Material Polycarbonate
Inflammability class(UL94) V-0
Ambient temperature                               [¡æ] -40~+125
Mechanical working life(mating cycles) ≥500
Contacts  
Material Copper alloy
Surface Hard-silver plated
Contact resistance Power area ≤0.3mΩ
  Signal area ≤1mΩ
Terminal Screw terminal
Power  area  Screw terminal tightening       1.5   2.5   4   6   10   16£¨ mm²£©
  1.2   2     3   3    3    3   [N·m]  
Signal ¡¡area  Screw terminal tightening 0.5                           [N·m]
Power¡¡area¡¡connection capacity(solid/stranded) 1.5-16mm²  (AWG16-6)
Signal  area¡¡connection capacity(solid/stranded) 0.5-2.5mm² (AWG20-14)
Screw M6/M3, (Steel£¬Ni plated )
Wire connecting  
Recommended stripping length/Power area14mm/Signal area 7.5mm
For solid wire, stripping wire to the appointed length, then tightening with rated torque.
For stranded wire: stripping wire to the appointed length, mating with corresponding type of ferrule, then tightening with rated torque.
Tightening process should be steady, can’t use explosive force.
 

DEGSON - DK-12/2-FC

Item Data
Inserts MatchingD16B Hoods&Housings
APPROVAL UL.CSA.VDE.CE.CQC
Test standard DIN EN61 984 / UL1977
¼«Êý(Poles) 12/2P+PE
The need for additional or dering crimp contacts Yes, 10/40A contacts
EN61984 Test data   /
Rated voltage                                    [V] 690/250
Rated current                                    [A] 40/10
pollution degree 3
Rated impulse voltage                            [KV] 8-Apr
Insulation resistance ≥1010Ω
UL/CSARated current                ¡¡¡¡¡¡¡¡¡¡  [V] 600/300
Material Polycarbonate
Inflammability class(UL94) V-0
Ambient temperature                        [¡æ] -40~+125
Mechanical working life(mating cycles) ≥500
Contacts
Material Copper alloy
Surface Hard-silver plated
Hard-gold plated
Contact resistance Power  area ≤0.3mΩ
Signal  area ≤3mΩ
Terminal Crimp terminal
Power area connection capacity(solid/stranded) 1.5-6.0mm² (AWG16-10)
Signal area connection capacity(solid/stranded) 0.14-2.5 mm²( AWG26-14)
Wire connecting
Recommended stripping length 6-9mm
 

DEGSON - DK-4/0-F

Item Data
Inserts MatchingD16B Hoods&Housings
APPROVAL UL.CSA.VDE.CE.CQC
Test standard DIN EN61 984 / UL1977
Poles 4/0P+PE
The need for additional or dering crimp contacts No
EN61984 Test data   /
Rated voltage                                  [V] 690
Rated current                                  [A] 80
pollution degree 3
Rated impulse voltage                          [KV] 8
Insulation resistance ≥1010Ω
UL/CSARated current                 ¡¡¡¡¡¡¡¡  [V] 600
Material Polycarbonate
Inflammability class(UL94) V-0
Ambient temperature                           [¡æ] -40~+125
Mechanical working life(mating cycles) ≥500
Contacts
Material Copper alloy
Surface Hard-silver plated
Contact resistance ≤0.3mΩ
Terminal Screw terminal
Screw terminal tightening)       1.5   2.5   4   6   10   16£¨ mm²£©
1.2   2     3   3    3    3   [N·m]  
Rated connection capacity(solid/stranded) 1.5-16mm²  (AWG16-6)
Screw M6, (Steel£¬Ni plated )
Wire connecting
Recommended stripping length 14mm;
For solid wire, stripping wire to the appointed length, then tightening with rated torque.
For stranded wire: stripping wire to the appointed length, mating with corresponding type of ferrule, then tightening with rated torque.
Tightening process should be steady, can’t use explosive force.

DEGSON - DK-8/24-FC

Item Data
Inserts MatchingD10B Hoods&Housings
APPROVAL UL.CSA.VDE.CE.CQC
Test standard DIN EN61 984 / UL1977
Poles 8/24P+PE
The need for additional or dering crimp contacts Yes,10/ 16A contacts
EN61984 Test data  
Rated voltage                                    [V] 400 / 160
Rated current                                    [A] 16-Oct
pollution degree 3
Rated impulse voltage                            [KV] 4 / 2.5
Insulation resistance ≥1010Ω
UL/CSARated current                ¡¡¡¡¡¡¡¡¡¡  [V] 600 / 300
Material Polycarbonate
Inflammability class(UL94) V-0
Ambient temperature                        [¡æ] -40~+125
Mechanical working life(mating cycles) ≥500
Contacts  
Material Copper alloy
Surface Hard-silver plated
  Hard-gold plated
Contact resistance ≤1mΩ/3mΩ
Terminal Crimp terminal
Power area connection capacity(solid/stranded) 0.5-4.0mm² (AWG20-12)
Signal area connection capacity(solid/stranded) 0.14-2.5 mm²( AWG26-12)
Wire connecting  
Recommended stripping length 6-8mm

DEGSON - DK-12/2-MC

Item Data
Inserts MatchingD16B Hoods&Housings
APPROVAL UL.CSA.VDE.CE.CQC
Test standard DIN EN61 984 / UL1977
¼«Êý(Poles) 12/2P+PE
The need for additional or dering crimp contacts Yes, 10/40A contacts
EN61984 Test data   /
Rated voltage                                    [V] 690/250
Rated current                                    [A] 40/10
pollution degree 3
Rated impulse voltage                            [KV] 8-Apr
Insulation resistance ≥1010Ω
UL/CSARated current                ¡¡¡¡¡¡¡¡¡¡  [V] 600/300
Material Polycarbonate
Inflammability class(UL94) V-0
Ambient temperature                        [¡æ] -40~+125
Mechanical working life(mating cycles) ≥500
Contacts
Material Copper alloy
Surface Hard-silver plated
Hard-gold plated
Contact resistance Power  area ≤0.3mΩ
Signal  area ≤3mΩ
Terminal Crimp terminal
Power area connection capacity(solid/stranded) 1.5-6.0mm² (AWG16-10)
Signal area connection capacity(solid/stranded) 0.14-2.5 mm²( AWG26-14)
Wire connecting
Recommended stripping length 6-9mm
 

DEGSON - DK-4/0-M

Item Data
Inserts MatchingD16B Hoods&Housings
APPROVAL UL.CSA.VDE.CE.CQC
Test standard DIN EN61 984 / UL1977
Poles 4/0P+PE
The need for additional or dering crimp contacts No
EN61984 Test data   /
Rated voltage                                  [V] 690
Rated current                                  [A] 80
pollution degree 3
Rated impulse voltage                          [KV] 8
Insulation resistance ≥1010Ω
UL/CSARated current                 ¡¡¡¡¡¡¡¡  [V] 600
Material Polycarbonate
Inflammability class(UL94) V-0
Ambient temperature                           [¡æ] -40~+125
Mechanical working life(mating cycles) ≥500
Contacts
Material Copper alloy
Surface Hard-silver plated
Contact resistance ≤0.3mΩ
Terminal Screw terminal
Screw terminal tightening)       1.5   2.5   4   6   10   16£¨ mm²£©
1.2   2     3   3    3    3   [N·m]  
Rated connection capacity(solid/stranded) 1.5-16mm²  (AWG16-6)
Screw M6, (Steel£¬Ni plated )
Wire connecting
Recommended stripping length 14mm;
For solid wire, stripping wire to the appointed length, then tightening with rated torque.
For stranded wire: stripping wire to the appointed length, mating with corresponding type of ferrule, then tightening with rated torque.
Tightening process should be steady, can’t use explosive force.

DEGSON - DK8/24-MC

Item Data
Inserts MatchingD10B Hoods&Housings
APPROVAL UL.CSA.VDE.CE.CQC
Test standard DIN EN61 984 / UL1977
Poles 8/24P+PE
The need for additional or dering crimp contacts Yes,10/ 16A contacts
EN61984 Test data  
Rated voltage                                    [V] 400 / 160
Rated current                                    [A] 16-Oct
pollution degree 3
Rated impulse voltage                            [KV] 4 / 2.5
Insulation resistance ≥1010Ω
UL/CSARated current                ¡¡¡¡¡¡¡¡¡¡  [V] 600 / 300
Material Polycarbonate
Inflammability class(UL94) V-0
Ambient temperature                        [¡æ] -40~+125
Mechanical working life(mating cycles) ≥500
Contacts  
Material Copper alloy
Surface Hard-silver plated
  Hard-gold plated
Contact resistance ≤1mΩ/3mΩ
Terminal Crimp terminal
Power area connection capacity(solid/stranded) 0.5-4.0mm² (AWG20-12)
Signal area connection capacity(solid/stranded) 0.14-2.5 mm²( AWG26-12)
Wire connecting  
Recommended stripping length 6-8mm

DEGSON - DSB-012-F

Item Data
Inserts MatchingD32B Hoods&Housings
APPROVAL UL.CSA.VDE.CE.CQC
Test standard DIN EN61 984 / UL1977
Poles 12P+PE
The need for additional or dering crimp contacts no
EN61984 Test data   /
Rated voltage                                  [V] 500
Rated current                                  [A] 35
pollution degree 3
Rated impulse voltage                          [KV] 6
Insulation resistance ≥1010Ω
UL/CSARated current                  ¡¡¡¡¡¡¡¡ [V] 600
Material Polycarbonate
Inflammability class(UL94) V-0
Ambient temperature                            [¡æ] -40~+125
Mechanical working life(mating cycles) ≥500
Contacts
Material Copper alloy
Surface Hard-silver plated
Contact resistance ≤1mΩ
Terminal Screw terminal
Rated torque                                   [N·m] 1.2
Rated connection capacity(solid/stranded) 6mm² (AWG10)
Screw M4, (Steel£¬Ni plated )
Wire connecting
Recommended stripping length 7.5mm;
For solid wire, stripping wire to the appointed length, then tightening with rated torque.
For stranded wire: stripping wire to the appointed length, mating with corresponding type of ferrule, then tightening with rated torque.
Tightening process should be steady, can’t use explosive force.
 

DEGSON - DSB-012-M

Item Data
Inserts MatchingD32B Hoods&Housings
APPROVAL UL.CSA.VDE.CE.CQC
Test standard DIN EN61 984 / UL1977
Poles 12P+PE
The need for additional or dering crimp contacts no
EN61984 Test data   /
Rated voltage                                  [V] 500
Rated current                                  [A] 35
pollution degree 3
Rated impulse voltage                          [KV] 6
Insulation resistance ≥1010Ω
UL/CSARated current                  ¡¡¡¡¡¡¡¡ [V] 600
Material Polycarbonate
Inflammability class(UL94) V-0
Ambient temperature                            [¡æ] -40~+125
Mechanical working life(mating cycles) ≥500
Contacts
Material Copper alloy
Surface Hard-silver plated
Contact resistance ≤1mΩ
Terminal Screw terminal
Rated torque                                   [N·m] 1.2
Rated connection capacity(solid/stranded) 6mm² (AWG10)
Screw M4, (Steel£¬Ni plated )
Wire connecting
Recommended stripping length 7.5mm;
For solid wire, stripping wire to the appointed length, then tightening with rated torque.
For stranded wire: stripping wire to the appointed length, mating with corresponding type of ferrule, then tightening with rated torque.
Tightening process should be steady, can’t use explosive force.

DEGSON - DSB-006-F

Item Data
Inserts MatchingD16B Hoods&Housings
APPROVAL UL.CSA.VDE.CE.CQC
Test standard DIN EN61 984 / UL1977
Poles 6P+PE
The need for additional or dering crimp contacts no
EN61984 Test data   /
Rated voltage                                    [V] 500
Rated current                                    [A] 35
pollution degree 3
Rated impulse voltage                            [KV] 6
Insulation resistance ≥1010Ω
UL/CSARated current                ¡¡¡¡¡¡¡¡¡¡  [V] 600
Material Polycarbonate
Inflammability class(UL94) V-0
Ambient temperature                             [¡æ] -40~+125
Mechanical working life(mating cycles) ≥500
Contacts  
Material Copper alloy
Surface Hard-silver plated
Contact resistance ≤1mΩ
Terminal  Screw terminal
Rated torque                                   [N·m] 1.2
Rated connection capacity(solid/stranded) 6mm² (AWG10)
Screw M4, (Steel£¬Ni plated )
Wire connecting  
Recommended stripping length 7.5mm;  
For solid wire, stripping wire to the appointed length, then tightening with rated torque.
For stranded wire: stripping wire to the appointed length, mating with corresponding type of ferrule, then tightening with rated torque.
Tightening process should be steady, can’t use explosive force.

DEGSON - DSB-006-M

Item Data
Inserts MatchingD16B Hoods&Housings
APPROVAL UL.CSA.VDE.CE.CQC
Test standard DIN EN61 984 / UL1977
Poles 6P+PE
The need for additional or dering crimp contacts no
EN61984 Test data   /
Rated voltage                                    [V] 500
Rated current                                    [A] 35
pollution degree 3
Rated impulse voltage                            [KV] 6
Insulation resistance ≥1010Ω
UL/CSARated current                ¡¡¡¡¡¡¡¡¡¡  [V] 600
Material Polycarbonate
Inflammability class(UL94) V-0
Ambient temperature                             [¡æ] -40~+125
Mechanical working life(mating cycles) ≥500
Contacts
Material Copper alloy
Surface Hard-silver plated
Contact resistance ≤1mΩ
Terminal  Screw terminal
Rated torque                                   [N·m] 1.2
Rated connection capacity(solid/stranded) 6mm² (AWG10)
Screw M4, (Steel£¬Ni plated )
Wire connecting
Recommended stripping length 7.5mm;
For solid wire, stripping wire to the appointed length, then tightening with rated torque.
For stranded wire: stripping wire to the appointed length, mating with corresponding type of ferrule, then tightening with rated torque.
Tightening process should be steady, can’t use explosive force.
 

DEGSON - DEE-092-FC

Item Data
Inserts MatchingD48B Hoods&Housings
APPROVAL UL.CSA.VDE.CE.CQC
Test standard DIN EN61 984 / UL1977
Poles 92P+PE
The need for additional or dering crimp contacts Yes, 16A contacts
EN61984 Test data   /
Rated voltage                                    [V] 500
Rated current                                    [A] 16
pollution degree 3
Rated impulse voltage                            [KV] 6
Insulation resistance ≥1010Ω
UL/CSARated current                 ¡¡¡¡¡¡¡¡¡¡  [V] 600
Material Polycarbonate
Inflammability class(UL94) V-0
Ambient temperature                        [¡æ] -40~+125
Mechanical working life(mating cycles) ≥500
Contacts
Material Copper alloy
Surface Hard-silver plated
Hard-gold plated
Contact resistance ≤1mΩ
Terminal Crimp terminal
Rated connection capacity(solid/stranded) 0.14—4.0mm² (AWG26-12)
Recommended stripping length 7.5mm
 

DEGSON - DEE-092-MC

Item Data
Inserts MatchingD48B Hoods&Housings
APPROVAL UL.CSA.VDE.CE.CQC
Test standard DIN EN61 984 / UL1977
Poles 92P+PE
The need for additional or dering crimp contacts Yes, 16A contacts
EN61984 Test data   /
Rated voltage                                    [V] 500
Rated current                                    [A] 16
pollution degree 3
Rated impulse voltage                            [KV] 6
Insulation resistance ≥1010Ω
UL/CSARated current                 ¡¡¡¡¡¡¡¡¡¡  [V] 600
Material Polycarbonate
Inflammability class(UL94) V-0
Ambient temperature                        [¡æ] -40~+125
Mechanical working life(mating cycles) ≥500
Contacts  
Material Copper alloy
Surface Hard-silver plated
  Hard-gold plated
Contact resistance ≤1mΩ
Terminal Crimp terminal
Rated connection capacity(solid/stranded) 0.14—4.0mm² (AWG26-12)
Recommended stripping length 7.5mm

1 - 24 of 112