DEGSON - TSC4 TRANSFORMER TERMINAL BLOCK

Item Data      
APPROVAL        
Test standard IEC/EN60998-1£º2004 / UL1059      
Pitch                                      [mm] /      
Poles 01P      
EN60998 Test data  VDE certificate NO. 40024836      
Rated voltage                              [V] 750      
Rated current                              [A] 32      
Rated connection capacity(solid/stranded) [mm2] 0.5~4      
Surge voltage category/pollution degree/material group III/2/I      
Withstanding Voltage                     [KV/min] 2      
Rated torque                              [N·m] 0.8      
UL1059Test data UL File Number E228872      
Use group B C D  
Rated voltage                             [V] 300 300 /  
Rated current                             [A] 20 20 /  
Rated connection capacity) (solid/stranded [AWG] 20~10      
Rated torque                            [Lb. in] 7.02      
General data /      
Screw M3.5      
Inflammability classUL94 V-0      
Ambient temperature                        [¡æ] -40~+105      
Relative humidity 5%-95%      
Inspection standard MIL-STD-105E II      
AQL 0.65      
Warranty 12 months      
Material and plating /      
Housing PA66      
Screws Steel£¬Zn plated      
Contact Copper alloy£¬Sn plated      
Cage Copper alloy£¬Ni plated      
Wire connecting        
10-12mm; Recommended stripping length 10-12mm;        
1.For solid wire, stripping wire to the appointed length, then tightening with rated torque.      
2.For stranded wire: stripping wire to the appointed length, mating with corresponding type of ferrule, then tightening with rated torque.
Tightening process should be steady, can’t use explosive force.

DEGSON - TSB4 TRANSFORMER TERMINAL BLOCK

Item Data        
APPROVAL          
Test standard IEC/EN60998-1£º2004 / UL1059        
Pitch                                      [mm] /        
Poles 01P        
EN60998 Test data   VDE certificate NO. 40024837        
Rated voltage                             [V] 450        
Rated current                              [A] 32        
Rated connection capacity (solid/stranded) [mm2] 0.5~4        
Surge voltage category/pollution degree/material group III/2/I        
Withstanding Voltage                    [KV/min] 3        
Rated torque                              [N·m] 1.2        
UL1059Test data UL File Number E228872        
Use group B C D    
Rated voltage                              [V] 600 600 600    
Rated current                              [A] 30 30 5    
Rated connection capacity (solid/stranded) [AWG] 12-20(SOL),12-18(STR)        
Rated torque                            [Lb. in] 10.53        
General data /        
Screw M4        
Inflammability classUL94 V-0        
Ambient temperature                       [¡æ] -40~+105        
Relative humidity 5%-95%        
Inspection standard MIL-STD-105E II        
AQL 0.65        
Warranty 12 months        
Material and plating /        
Housing PA66        
Screws Steel£¬Ni plated        
Contact Copper alloy£¬Sn plated        
Wire connecting          
8-10mm; Recommended stripping length 8-10mm;          
1.For solid wire, stripping wire to the appointed length, then tightening with rated torque.        
2.For stranded wire: stripping wire to the appointed length, mating with corresponding type of ferrule, then tightening with rated torque.
Tightening process should be steady, can’t use explosive force  

DEGSON - TSB 2.5 TRANSFORMER TERMINAL BLOCK

Item Data        
APPROVAL          
Test standard IEC/EN60998-1£º2004 / UL1059        
Pitch                                      [mm] 9.5        
Poles 02~03P        
EN60998 Test data  VDE certificate NO. 40024859        
Rated voltage                              [V] 250        
Rated current                              [A] 24        
Rated connection capacity(solid/stranded) [mm2] 0.5~2.5        
Surge voltage category/pollution degree/material group III/2/I        
Withstanding Voltage                     [KV/min] 2        
Rated torque                              [N·m] 0.8        
UL1059Test data UL File Number E228872        
Use group B C D    
Rated voltage                             [V] 600 600 600    
Rated current                            [A] 20 20 5    
Rated connection capacity (solid/stranded) [AWG] 20~12        
Rated torque                            [Lb. in] 7.02        
General data /        
Screw M3.5        
Inflammability class UL94 V-0        
Ambient temperature                        [¡æ] -40~+105        
Relative humidity 5%-95%        
Inspection standard MIL-STD-105E II        
AQL 0.65        
Warranty 12 months        
Material and plating /        
Housing PA66        
Screws Steel£¬Ni plated        
Contact Copper alloy£¬Sn plated        
Wire connecting          
Recommended stripping length 8-10mm;          
1.For solid wire, stripping wire to the appointed length, then tightening with rated torque.        
2.For stranded wire: stripping wire to the appointed length, mating with corresponding type of ferrule, then tightening with rated torque.
Tightening process should be steady, can’t use explosive force.

DEGSON - TS 10 TRANSFORMER TERMINAL BLOCK

Item Data        
APPROVAL          
Test standard IEC/EN60998-1£º2004 / UL1059        
Pitch                                      [mm] /        
Poles 01P        
EN60998 Test data   VDE certificate NO. 40024727        
Rated voltage                             [V] 750        
Rated current                            [A] 57        
Rated connection capacity(solid/stranded) [mm2] 4~10        
Surge voltage category/pollution degree/material group III/2/I        
Withstanding Voltage                    [KV/min] 8        
Rated torque                               [N·m] 2        
UL1059Test data UL File Number E228872        
Use group B C D    
Rated voltage                              [V] 300 300 /    
Rated current                              [A] 55 55 /    
Rated connection capacity (solid/stranded) [AWG] 12~6        
Rated torque                            [Lb. in] 17.54        
General data /        
Screw M5        
Inflammability class UL94 V-0        
Ambient temperature                        [¡æ] -40~+105        
Relative humidity 5%-95%        
Inspection standard MIL-STD-105E II        
AQL 0.65        
Warranty 12 months        
Material and plating /        
Housing PA66        
Screws Steel£¬Zn plated        
Contact Copper alloy£¬Sn plated        
Wire connecting          
Recommended stripping length 8-10mm;          
1.For solid wire, stripping wire to the appointed length, then tightening with rated torque.        
2.For stranded wire: stripping wire to the appointed length, mating with corresponding type of ferrule, then tightening with rated torque.
Tightening process should be steady, can’t use explosive force.

DEGSON - TS4 TRANSFORMER TERMINAL BLOCK

Item Data        
APPROVAL          
Test standard IEC/EN60998-1£º2004 / UL1059        
Pitch                                     [mm] /        
Poles 01P        
EN60998 Test data   VDE certificate NO. 40024867        
Rated voltage                              [V] 250        
Rated current                             [A] 32        
Rated connection capacity(solid/stranded) [mm2] 0.75~4        
Surge voltage category/pollution degree/material group III/2/I        
Withstanding Voltage                     [KV/min] 2        
Rated torque                               [N·m] 1.2        
UL1059Test data UL File Number E228872        
Use group B C D    
Rated voltage                             [V] 300 300 300    
Rated current                              [A] 20 10 10    
Rated connection capacity (solid/stranded) [AWG] 20~12        
Rated torque                            [Lb. in] 10.53        
General data /        
Screw M4        
Inflammability class UL94 V-0        
Ambient temperature                       [¡æ] -40~+105        
Relative humidity 5%-95%        
Inspection standard MIL-STD-105E II        
AQL 0.65        
Warranty 12 months        
Material and plating /        
Housing PA66        
Screws Steel£¬Zn plated        
Contact Copper alloy£¬Sn plated        
Wire connecting          
Recommended stripping length 8-10mm;          
1.For solid wire, stripping wire to the appointed length, then tightening with rated torque.        
2.For stranded wire: stripping wire to the appointed length, mating with corresponding type of ferrule, then tightening with rated torque.
Tightening process should be steady, can’t use explosive force.  

DEGSON - TS2.5 TRANSFORMER TERMNAL BLOCK

Item Data        
APPROVAL          
Test standard IEC/EN60998-1£º2004 / UL1059        
Pitch                                    [mm] 7.5        
Poles 02~03P        
EN60998 Test data   VDE certificate NO. 40024866        
Rated voltage                              [V] 800        
Rated current                             [A] 24        
Rated connection capacity(solid/stranded) [mm2] 0.5~2.5        
Surge voltage category/pollution degree/material group III/2/I        
Withstanding Voltage                     [KV/min] 3.5        
Rated torque                              [N·m] 0.5        
UL1059Test data UL File Number E228872        
Use group B C D    
Rated voltage                              [V] 300 300 /    
Rated current                              [A] 10 10 /    
Rated connection capacity (solid/stranded) [AWG] 24-14        
Rated torque                            [Lb. in] 4.43        
General data /        
Screw M3        
Inflammability class UL94 V-0        
Ambient temperature                        [¡æ] -40~+105        
Relative humidity 5%-95%        
Inspection standard MIL-STD-105E II        
AQL 0.65        
Warranty 12 months        
Material and plating /        
Housing PA66        
Screws Steel£¬Zn plated        
Contact Copper alloy£¬Sn plated        
Wire connecting          
Recommended stripping length 8-10mm;          
1.For solid wire, stripping wire to the appointed length, then tightening with rated torque.        
2.For stranded wire: stripping wire to the appointed length, mating with corresponding type of ferrule, then tightening with rated torque.
Tightening process should be steady, can’t use explosive force.  

DEGSON - TS2.5-02P-15-01AH

Degson Terminal Bloocks TS2.5-02P-15-01AH

Description: Transformer terminal block 2p 7.5mm 24A 250V AWG24-14

DEGSON - TS4-01P-15-01AH

DEGSON Terminal Blocks TS4-01P-15-01AH

Description: Transformer terminal block 1p 13mm 32A 250V AWG24-10

Degson TSZB4

Degson TZB4

Degson TSCK4

Degson TSCBF4

Degson TSF2.5

Degson TSCB4

Degson TSCF4

Degson TSC10

Degson TSC6

Degson TSC4

Degson TSB4

Degson TSB2.5

Degson TS10

Degson TS4

Degson TS2.5

 

Recent Updates