19, Jalan PJS 3/59,
Taman Sri Manja,
46000 Petaling Jaya,
Selangor, Malaysia.
+603-7783 2257
+603-7783 4316
+603-7783 4318
+603-7783 4318
1 - 24 of 32 | |||
Lascar Dual Channel High Accuracy Thermistor WiFi (EL-WiFi-DTP+) | Lascar Handheld Temperature Recorder (EL-ENVIROPAD-TC) | Lascar 21CFR-compliant Thermocouple Temperature Data Logger with USB (EL-21CFR-TC) | Lascar Wireless High Accuracy Temperature Data Logger with Dual Thermistor Probes (EL-MOTE-DTP+)Overview· Alarm functions include a built in sounder and LED · Quick, wireless App based configuration · Stores data internally if device loses WiFi connection and automatically uploads it to the Cloud once reconnected · Suitable for indoor and outdoor applications · Industry leading 2 years battery life · Add first logger for free (minimal charges for additional devices) Specification-40 to +125°C -40 to +257°F Typical Accuracy ±0.2°C ±0.4°F Battery Life Up to 2 years 4 x 1.5V AA cells Dimensions 93 x 93 x 32mm 3.7 x 3.7 x 1.3' IP Rating 67 Probe Cable Length 3m (118.1')
|
Lascar WiFi Vaccine Monitoring Kit (EL-WiFi-VAC)OverviewThe device will store data internally if it loses WiFi connection and automatically uploads it to the Cloud once reconnected. Use the EasyLog Cloud Apps for Android and Apple to easily setup your device and access your data anytime, anywhere. Specification-40 to 60°C (-40 to 140°F) Measurement resolution 0.01°C (0.01°F) Measurement accuracy (typical) ±0.2°C (-15 to +60°C) ±0.4°F (+5 to +140°F) Measurement accuracy (maximum) ±0.6°C (-40 to +60°C/ -40 to +140°F) Operating temperature (module) -20 to +60°C (-4 to +140°F) Readings Unlimited Logging Rate User selectable between 10 seconds and 12 hours Battery Life Rechargeable Battery / 6 Months Battery Life / Mains Powered Option Calibration Certificate Supplied at 2 and 8°C Application Info | Lascar WiFi Thermistor Probe Data Logging Sensor (EL-WiFi-TP+)OverviewEasyLog Cloud gives access to each data logger, and data collected from any internet-enabled device. Change data logger settings remotely, receive email alerts of alarm conditions, link sensors from multiple sites into one account and assign multiple user privileges. The device will store data internally if it loses WiFi connection and automatically uploads it to the Cloud once reconnected. Use the EasyLog Cloud Apps for Android and Apple to easily setup your device and access your data anytime, anywhere. Specification-40 to 125°C (-40 to 257°F) Measurement resolution 0.01°C (0.02°F) Measurement accuracy (Typical) ±0.2°C (-15 to +80°C) ±0.4°F (+5 to +176°F) Measurement accuracy (Maximum) ±0.6°C (-40 to +125°C) ±1.1°F (-40 to +257°F) Operating temperature (module) -20 to 60°C (-4 to 140°F) Readings Unlimited Logging Rate User selectable between 10 seconds and 12 hours Battery 6 months Rechargeable Battery / 6 Months Battery Life / Mains Powered Option Calibration Certificate Available Separately Probe Cable Length 3m (118.1') Application Info· Environmental and weather monitoring · Agricultural and livestock · Food & drink · Building & site monitoring | Lascar WiFi High Accuracy Temperature Data Logger (EL-WiFi-T+)OverviewEasyLog Cloud gives access to each data logger, and data collected from any internet-enabled device. Change data logger settings remotely, receive email alerts of alarm conditions, link sensors from multiple sites into one account and assign multiple user privileges. The device will store data internally if it loses WiFi connection and automatically uploads it to the Cloud once reconnected. Use the EasyLog Cloud Apps for Android and Apple to easily setup your device and access your data anytime, anywhere. Specification20 to +60°C /( -4 to +140°F) Accuracy ±0.1°C / ±0.2°F Readings Unlimited Logging Rate User selectable between 10 seconds and 12 hours Battery Rechargeable Battery / 6 Months Battery Life / Mains Powered Option Calibration Certificate Available Separately Application Info | Lascar USB Vaccine Monitoring Kit (EL-USB-VAC)OverviewSpecification-40 to 60°C (-40 to 140°F) Accuracy ±0.1°C (±0.2°F) (typ) Logging rate User selectable between 1 second and 12 hours Operating temperature -35 to 60°C (-31 to 140°F) Battery life 2 Years Calibration Certificate Supplied at 2 and 8°C
|
Lascar Panel Mountable Four-Channel Temp Data Logger (EL-SGD 43-ATP)OverviewSpecification-40°C to +125°C (-40°F to +257°F) Internal Resolution 0.01°C (0.01°F) Temperature Accuracy ±1.0°C (±1.8°F) Number of Readings (per channel) 100,000 Logging Rate 5 seconds to 12 hours Number of Channels Up to 4 Outside Dimensions 119.3 x 79.8 x 31.3 mm (4.7 x 3.1 x 1.2 in) Communications Protocols USB Application Info | Lascar High Accuracy Wireless Temperature Data Logger (EL-MOTE-T+)Overview· Alarm functions include a built in sounder and LED · Quick, wireless App based configuration · Stores data internally if device loses WiFi connection and automatically uploads it to the Cloud once reconnected · Suitable for indoor and outdoor applications · Industry leading 2 years battery life · Add first logger for free (minimal charges for additional devices) Specification-20 to +60°C -4 to +140°F Typical Accuracy ±0.15°C ±0.3°F Battery Life Up to 2 years 4 x 1.5V AA Dimensions 93 x 93 x 32mm 3.7 x 3.7 x 1.3' IP Rating 67
| Lascar High Accuracy Dual Channel Thermistor Data Logger with Graphic Screen and Audible Alarm (EL-GFX-DTP+)OverviewSpecification-40 to 125°C (-40 to 257°F) Logger accuracy (overall error) ±0.1°C (±0.2°F) Operating temperature -10 to 40°C (14 to 104°F) Logging rate User selectable between 2 seconds and 1 hour Calibration certificate Available Separately Probe Cable Length 3m (118.1')
| Lascar High Accuracy 21CFR WiFi Thermistor Probe Data Logger (EL-WiFi-21CFR-DTC)OverviewWhy buy a 21CFR logger? The 21 CFR Part 11 regulations issued by the US Food and Drug Administration (FDA) give the criteria under which electronic records can be considered by the FDA as equivalent to paper records. If you need to meet these regulations or have enhanced data security requirements then you should choose one of our 21CFR loggers, otherwise our standard loggers will suffice. Learn more about 21 CFR Part 11. 21CFR Cloud subscription delivers all of the flexibility of remote monitoring and can be installed as part of a 21CFR compliant system. Features include permission-based use, authority level sign-off and full system audit to ensure data monitored and collected is regulated to 21CFR Part 11 standard. This device requires a subscription to our EasyLog 21CFR Cloud service. Specification-40 to 125°C (-40 to 257°F) Measurement resolution 0.01°C (0.01°F) Measurement accuracy (Typical) ±0.2°C (-15 to +80°C) ±0.4°F (+5 to +176°F) Measurement accuracy (Maximum) ±0.6°C (-40 to +125°C/ -40 to +257°F) Operating temperature (module) -20 to 60°C (-4 to 140°F) Readings Unlimited Logging Rate User selectable between 10 seconds and 12 hours Battery Life 6 Months Calibration Certificate Available Separately Probe Cable Length 3m (118.1') Application Info |
Lascar Dual Channel Wireless Thermistor Data Logger (EL-MOTE-DTP)Overview· Alarm functions include a built in sounder and LED · Quick, wireless App based configuration · Stores data internally if device loses WiFi connection and automatically uploads it to the Cloud once reconnected · Suitable for indoor and outdoor applications · Industry leading 2 years battery life · Add first logger for free (minimal charges for additional devices) Specification-40 to +125°C -40 to +257°F Typical Accuracy ±0.8°C ±1.5°F Battery Life Up to 2 years 4 x 1.5V AA cells Dimensions 93 x 93 x 32mm 3.7 x 3.7 x 1.3' IP Rating 67 Probe Cable Length 3m (118.1')
| Lascar Dual Channel WiFi Vaccine Monitoring Kit (EL-WiFi-VAC2)
| Lascar Dual Channel High Accuracy Thermistor 21CFR WiFi Sensor (EL-WiFi-21CFR-DTP+)OverviewWhy buy a 21CFR logger? The 21 CFR Part 11 regulations issued by the US Food and Drug Administration (FDA) give the criteria under which electronic records can be considered by the FDA as equivalent to paper records. If you need to meet these regulations or have enhanced data security requirements then you should choose one of our 21CFR loggers, otherwise our standard loggers will suffice. Learn more about 21 CFR Part 11. 21CFR Cloud subscription delivers all of the flexibility of remote monitoring and can be installed as part of a 21CFR compliant system. Features include permission-based use, authority level sign-off and full system audit to ensure data monitored and collected is regulated to 21CFR Part 11 standard. This device requires a subscription to our EasyLog 21CFR Cloud service. Specification-40 to +125°C / -40 to +257°F Accuracy ±0.2°C / ±0.4°F Measurement Range Unlimited Logging Rate User selectable between 10 seconds and 12 hours Battery Life 6 Months Calibration Certificate Available Separately Probe Cable Length 3m (118.1') Application Info | Lascar Dual Channel GFX Vaccine Monitoring Kit (EL-GFX-VAC2)OverviewSpecification-40 to 60°C (-40 to 140°F) Accuracy (overall error) ±0.1°C (±0.2°F) Operating temperature -10 to 40°C (14 to 104°F) Logging rate User selectable between 2 seconds and 1 hour Calibration certificate Supplied at 2 and 8°C
|
Lascar Dual Channel 21CFR WiFi Vaccine Monitoring Kit (EL-WiFi-21CFR-VAC2)OverviewWhy buy a 21CFR logger? The 21 CFR Part 11 regulations issued by the US Food and Drug Administration (FDA) give the criteria under which electronic records can be considered by the FDA as equivalent to paper records. If you need to meet these regulations or have enhanced data security requirements then you should choose one of our 21CFR loggers, otherwise our standard loggers will suffice. Learn more about 21 CFR Part 11. 21CFR Cloud subscription delivers all of the flexibility of remote monitoring and can be installed as part of a 21CFR compliant system. Features include permission-based use, authority level sign-off and full system audit to ensure data monitored and collected is regulated to 21CFR Part 11 standard. This device requires a subscription to our EasyLog 21CFR Cloud service. Specification-40 to +60°C / -40 to +140°F Accuracy ±0.2°C / ±0.4°F Logging Rate User selectable between 10 seconds and 12 hours Battery Life 6 Months Calibration Certificate Supplied at 2 and 8°C Application Info | Lascar 21CFR WiFi Vaccine Monitoring Kit (EL-WiFi-21CFR-VAC)OverviewWhy buy a 21CFR logger? The 21 CFR Part 11 regulations issued by the US Food and Drug Administration (FDA) give the criteria under which electronic records can be considered by the FDA as equivalent to paper records. If you need to meet these regulations or have enhanced data security requirements then you should choose one of our 21CFR loggers, otherwise our standard loggers will suffice. Learn more about 21 CFR Part 11. 21CFR Cloud subscription delivers all of the flexibility of remote monitoring and can be installed as part of a 21CFR compliant system. Features include permission-based use, authority level sign-off and full system audit to ensure data monitored and collected is regulated to 21CFR Part 11 standard. This device is supplied with a high accuracy glycol bottle thermistor probe and requires a subscription to our EasyLog 21CFR Cloud service. Specification-40 to 60°C (-40 to 140°F) Measurement resolution 0.01°C (32°F) Measurement accuracy (typical) ±0.2°C (-15 to +60°C) ±0.4°F (+5 to +140°F) Measurement accuracy (maximum) ±0.6°C (-40 to +60°C/ -40 to +140°F) Operating temperature (module) -20 to +60°C (-4 to +140°F) Readings Unlimited Logging Rate User selectable between 10 seconds and 12 hours Battery Life 6 Months Calibration Certificate Supplied at 2 and 8°C Application Info | Lascar 21CFR WiFi Thermocouple Data Logger (EL-WiFi-21CFR-TC)OverviewWhy buy a 21CFR logger? The 21 CFR Part 11 regulations issued by the US Food and Drug Administration (FDA) give the criteria under which electronic records can be considered by the FDA as equivalent to paper records. If you need to meet these regulations or have enhanced data security requirements then you should choose one of our 21CFR loggers, otherwise our standard loggers will suffice. Learn more about 21 CFR Part 11. 21CFR Cloud subscription delivers all of the flexibility of remote monitoring and can be installed as part of a 21CFR compliant system. Features include permission-based use, authority level sign-off and full system audit to ensure data monitored and collected is regulated to 21CFR Part 11 standard. This device requires a subscription to our EasyLog 21CFR Cloud service. Specification0 to +200°C (+32 to +392°F) Measurement Range K Type -200 to +1,300°C (-328 to +2,372°F) Measurement Range J Type -200 to +1,190°C (-328 to +2,174°F) Measurement Range T Type -200 to +390°C (-328 to +734°F) Accuracy ±1.5°C (±3°F) Readings Unlimited Logging Rate User selectable between 10 seconds and 12 hours Battery Life 6 Months Calibration Certificate Available Separately Application Info | Lascar 21CFR WiFi Thermistor Probe Data Logger (EL-WiFi-21CFR-TP)OverviewWhy buy a 21CFR logger? The 21 CFR Part 11 regulations issued by the US Food and Drug Administration (FDA) give the criteria under which electronic records can be considered by the FDA as equivalent to paper records. If you need to meet these regulations or have enhanced data security requirements then you should choose one of our 21CFR loggers, otherwise our standard loggers will suffice. Learn more about 21 CFR Part 11. 21CFR Cloud subscription delivers all of the flexibility of remote monitoring and can be installed as part of a 21CFR compliant system. Features include permission-based use, authority level sign-off and full system audit to ensure data monitored and collected is regulated to 21CFR Part 11 standard. This device requires a subscription to our EasyLog 21CFR Cloud service. Specification-40 to 125 °C (-40 to 257 °F) Measurement resolution 0.1 °C Measurement accuracy ±0.6 °C (-10 to +70°C) ±1.0 °C (-40 to +125°C) Operating temperature (module) -20 to 60 °C (-4 to 140 °F) Readings Unlimited Logging Rate User selectable between 10 seconds and 12 hours Battery Life 6 Months Calibration Certificate Available Separately Probe Cable Length 1m (39.4') Application Info |
Lascar 21CFR WiFi Temperature Data Logger (EL-WiFi-21CFR-T)OverviewThe device will store data internally if it loses WiFi connection and automatically uploads it to the Cloud once reconnected. Why buy a 21CFR logger? The 21 CFR Part 11 regulations issued by the US Food and Drug Administration (FDA) give the criteria under which electronic records can be considered by the FDA as equivalent to paper records. If you need to meet these regulations or have enhanced data security requirements then you should choose one of our 21CFR loggers, otherwise our standard loggers will suffice. Learn more about 21 CFR Part 11. 21CFR Cloud subscription delivers all of the flexibility of remote monitoring and can be installed as part of a 21CFR compliant system. Features include permission-based use, authority level sign-off and full system audit to ensure data monitored and collected is regulated to 21CFR Part 11 standard. This device requires a subscription to our EasyLog 21CFR Cloud service. Specification-20 to +60°C / -4 to +140°F) Accuracy ±0.5°C / ±1°F Readings Unlimited Logging Rate User selectable between 10 seconds and 12 hours Battery Life 6 Months Calibration Certificate Available Separately Application Info | Lascar 21CFR WiFi High Accuracy Temperature Data Logger (EL-WiFi-21CFR-T+)OverviewWhy buy a 21CFR logger? The 21 CFR Part 11 regulations issued by the US Food and Drug Administration (FDA) give the criteria under which electronic records can be considered by the FDA as equivalent to paper records. If you need to meet these regulations or have enhanced data security requirements then you should choose one of our 21CFR loggers, otherwise our standard loggers will suffice. Learn more about 21 CFR Part 11. 21CFR Cloud subscription delivers all of the flexibility of remote monitoring and can be installed as part of a 21CFR compliant system. Features include permission-based use, authority level sign-off and full system audit to ensure data monitored and collected is regulated to 21CFR Part 11 standard. This device requires a subscription to our EasyLog 21CFR Cloud service. Specification20 to +60°C /( -4 to +140°F) Accuracy ±0.1°C / ±0.2°F Readings Unlimited Logging Rate User selectable between 10 seconds and 12 hours Battery Life 6 Months Calibration Certificate Available Separately Application InfoFor application stories on our data loggers, visit our case studies section. Calibration | Lascar 21CFR WiFi Dual Channel Thermocouple Probe Data Logging Sensor (EL-WiFi-21CFR-DTC)OverviewWhy buy a 21CFR logger? The 21 CFR Part 11 regulations issued by the US Food and Drug Administration (FDA) give the criteria under which electronic records can be considered by the FDA as equivalent to paper records. If you need to meet these regulations or have enhanced data security requirements then you should choose one of our 21CFR loggers, otherwise our standard loggers will suffice. Learn more about 21 CFR Part 11. 21CFR Cloud subscription delivers all of the flexibility of remote monitoring and can be installed as part of a 21CFR compliant system. Features include permission-based use, authority level sign-off and full system audit to ensure data monitored and collected is regulated to 21CFR Part 11 standard. This device is supplied with a high accuracy glycol bottle thermistor probe and requires a subscription to our EasyLog 21CFR Cloud service. Specification-40 to 60°C (-40 to 140°F) Measurement resolution 0.01°C (32°F) Measurement accuracy (typical) ±0.2°C (-15 to +60°C) ±0.4°F (+5 to +140°F) Measurement accuracy (maximum) ±0.6°C (-40 to +60°C/ -40 to +140°F) Operating temperature (module) -20 to +60°C (-4 to +140°F) Readings Unlimited Logging Rate User selectable between 10 seconds and 12 hours Battery Life 6 Months Calibration Certificate Supplied at 2 and 8°C Application Info | Lascar 21CFR USB Vaccine Monitoring Kit (EL-21CFR-VAC) |
1 - 24 of 32 |