19, Jalan PJS 3/59,
Taman Sri Manja,
46000 Petaling Jaya,
Selangor, Malaysia.
+603-7783 4318
MEGGER GTS-300 Safety Ground and ground grid test setOVERVIEW
The GTS-300 is a two-piece test set designed to ensure the integrity of grounding systems and to test personal safety grounds. The high-current method of testing ground grid continuity and connections is a reliable, accurate method of detecting faults in the ground system. | MEGGER DET4TD2, DET4TR2, DET4TC2 AND DET4TCR2OVERVIEW
The DET4 contractor series includes -
The DET4TD, DET4TC and DET4TCR replace the DET5/4R and DET5/4D. | MEGGER DET3TC 3 Terminal Earth Resistance TesterOVERVIEW
The DET3TC is capable of testing on-site grounds without disconnecting the utility connection | MEGGER ETK - Earth Tester Kit Electrode & Soil Resistivity Stake and Wire KitOVERVIEW
Megger have been a pioneer of earth/ground testing and provide exceptional test meters with accessory kits for this purpose. The Megger Earth Test Kit (ETK models) are designed to be as practical as possible. Housed in a holdall, the kits are stored neatly, well protected and easy to transport. Much care has been taken to produce a variety of kits to meet needs. In use the test leads are fitted and retained on reels with smooth action. Simply run out the test lead from the instrument to the test point, clip the end directly into the spike and test, easy. When the test is complete, unclip the test leads and wind them in. The kits come in different combinations to meet different needs and constraints. They are supplied with a tape measure to ensure accurate placement of test spikes/pins. The reels can be daisy chained together to provide longer lengths in manageable chunks. |
MEGGER DET2/3 High Resolution Earth TesterOVERVIEW
The DET2/3 is a robust and compact automatic earth (ground) test instrument designed to measure earth electrode resistance and soil resistivity. For use on large or more complex earth systems, which include communications earth systems and difficult test environments, it can be used to test in accordance with BS 7430 (earthing / grounding), BS-EN-62305 (Lightning Protection), BS-EN-50122-1 (Railway Applications), and IEEE Standard 81. Test frequency, test current and filtering can be quickly and easily adjusted so that adverse conditions, which can influence the test, can be overcome, and a wide band of test current frequencies, with a resolution of 0.5 Hz, can be used to eliminate errors caused by noise in the earth. With its microprocessor controlled system it provides a flexible and ‘user-friendly’ approach to earth tests by the provision of excellent error detection capabilities and full test information shown on a large colour display. The DET2/3 can provide a live trace of its measurements, which graphically shows the amount of noise from the system under test - a powerful diagnostic tool for the expert earth (ground) test engineer. The DET2/3 also includes an automatic frequency selection feature that scans for frequencies with the lowest noise level and then runs a test at that frequency. The selected test current frequency, test current level and the increased filtering option are stored in memory for use in subsequent tests. Use of the latest processors and a large internal memory allows for immediate calculations of resistivity (Wenner or Schlumberger method) and the ability to save a complete days’ worth of test results. Test result data can be downloaded directly through a USB flash drive or straight to a Windows PC running PowerDB™ software. |