DEGSON DGV4-10A THROUGH-WALL TERMINAL BLOCK

Item Data    
APPROVAL /    
Test standard IEC60947-7-1    
Pitch                                               [mm] 8.1    
Poles 01P-XXP    
IEC60947-7-1 Test data    /    
Rated voltage                                         [V] 400    
Rated current                                         [A] 41    
Rated connection capacity (solid/stranded)            [mm²] 0.2-6    
Surge voltage category/pollution degree/material group III/3/I    
Rated impulse voltage                                 [KV] 6    
Rated torque                                       [N·m] 0.5    
UL1059Test data UL1059    
Use group B C D
Rated voltage                                       [V] 300 / /
Rated current                                       [A] 30 / /
Rated connection capacity (solid/stranded)             [AWG] 30-Oct    
Rated torque                                       [Lb. in] 4.43    
General data /    
Screw M3    
Inflammability class UL94 V-0    
Ambient temperature                                 [”ę] -40~+105    
Relative humidity 5%-95%    
Inspection standard MIL-STD-105E   II    
AQL 0.65    
Warranty 12   months    
Material and plating /    
Housing PA66    
Screws Copper   alloy£¬Sn plated    
Current carrier Copper   alloy£¬Sn plated    
Cage Copper   alloy£¬Ni plated    
Wire connecting      
Recommended stripping length9.0mm;      
For solid wire, stripping wire to the appointed length, then tightening with rated torque.    
For stranded wire: stripping wire to the appointed length, mating with corresponding type of ferrule, then tightening with rated torque.
Tightening process should be steady, can’t use explosive force.

DEGSON DGP95 THROUGH-WALL TERMINAL BLOCK

Item Data    
APPROVAL /    
Test standard IEC60947-7-1    
Pitch                                               [mm] 8.1    
Poles 01P-XXP    
IEC60947-7-1 Test data    /    
Rated voltage                                         [V] 400    
Rated current                                         [A] 41    
Rated connection capacity (solid/stranded)            [mm²] 0.2-6    
Surge voltage category/pollution degree/material group III/3/I    
Rated impulse voltage                                 [KV] 6    
Rated torque                                       [N·m] 0.5    
UL1059Test data UL1059    
Use group B C D
Rated voltage                                       [V] 300 / /
Rated current                                       [A] 30 / /
Rated connection capacity (solid/stranded)             [AWG] 30-Oct    
Rated torque                                       [Lb. in] 4.43    
General data /    
Screw M3    
Inflammability class UL94 V-0    
Ambient temperature                                 [”ę] -40~+105    
Relative humidity 5%-95%    
Inspection standard MIL-STD-105E   II    
AQL 0.65    
Warranty 12   months    
Material and plating /    
Housing PA66    
Screws Copper   alloy£¬Sn plated    
Current carrier Copper   alloy£¬Sn plated    
Cage Copper   alloy£¬Ni plated    
Wire connecting      
Recommended stripping length9.0mm;      
For solid wire, stripping wire to the appointed length, then tightening with rated torque.    
For stranded wire: stripping wire to the appointed length, mating with corresponding type of ferrule, then tightening with rated torque.
Tightening process should be steady, can’t use explosive force.

DEGSON - DGH10 THROUGH-WALL TERMINAL BLOCK

Item Data      
APPROVAL /      
Test standard IEC60947-7-4      
Pitch                                     [mm] 10.1      
Poles 01P      
IEC60947 Test data /      
Rated voltage                             [V] 500      
Rated current                          [A] 76      
Rated connection capacity(solid/stranded) [mm²] 0.5-16      
Surge voltage category/pollution degree/material group III/2/I      
Rated impulse voltage      [KV] 8      
Rated torque                              [N.m] 1.2      
UL1059Test data UL 1059      
Use group B C D  
Rated voltage                              [V] 300 / /  
Rated current                             [A] 65 / /  
Rated connection capacity(solid/stranded) [AWG] 24-Jun      
Rated torque          [Lb. in] 10.53      
General data /      
Screw M4      
Inflammability class UL94 V0      
Ambient temperature                       [”ę] -40~+105      
Relative humidity 5%-95%      
Inspection standard MIL-STD-105E II      
AQL 0.65      
Warranty 12 months      
Material and plating /      
Housing PA66      
Screw Steel£¬Zn plated      
CurrentCarrier Copper alloy£¬Sn plated      
Cage Copper alloy£¬Ni plated      
Wire connecting        
Recommended stripping length 10mm;        
For solid wire, stripping wire to the appointed length, then tightening with rated torque.      
For stranded wire: stripping wire to the appointed length, mating with corresponding type of ferrule, then tightening with rated torque.
Tightening process should be steady, can’t use explosive force.

DEGSON - DG4F THROUGH-WALL TERMINAL BLOCK

Item Data      
APPROVAL /      
Test standard IEC60947-7-1      
Pitch                                      [mm] 12.2      
Poles 01P      
IEC60947 Test data   /      
Rated voltage                              [V] 400      
Rated current                             [A] 6      
Rated connection capacity(solid/stranded) [mm²] 0.2~6      
Surge voltage category/pollution degree/material group III/2/I      
Rated impulse voltage                   [KV] 4      
Rated torque                               [N.m] 0.5      
UL1059Test data UL 1059      
Use group B C D  
Rated voltage                              [V] 300 / /  
Rated current                              [A] 10 / /  
Rated connection capacity (solid/stranded) [AWG] 30~10      
Rated torque                            [Lb. in] 4.43      
General data /      
Screw M3      
Inflammability class UL94 V0      
Ambient temperature                        [”ę] -40~+105      
Relative humidity 5%-95%      
Inspection standard MIL-STD-105E II      
AQL 0.65      
Warranty 12 months      
Material and plating /      
Housing PA66      
Screw Copper alloy£¬Ni plated      
Contact Copper alloy£¬Sn plated      
Cage Copper alloy£¬Ni plated      
Current carrier Copper alloy£¬Sn plated      
Wire connecting        
Recommended stripping length 8mm;        
1.For solid wire, stripping wire to the appointed length, then tightening with rated torque.      
2.For stranded wire: stripping wire to the appointed length, mating with corresponding type of ferrule, then tightening with rated torque.
 Tightening process should be steady, can’t use explosive force.

DEGSON - DGH4 THROUGH-WALL TERMINAL BLOCK

Item Data          
APPROVAL            
Test standard IEC60998-1          
Pitch                                      [mm] 8.1          
Poles 01P          
IEC60998 Test data  /          
Rated voltage                              [V] 400          
Rated current                            [A] 41          
Rated connection capacity(solid/stranded) [mm²] 0.2~6          
Surge voltage category/pollution degree/material group III/2/I          
Withstanding Voltage                    [KV/min] 2.5          
Rated torque                              [N.m] 0.5          
UL1059Test data UL File Number E228872          
Use group B C D      
Rated voltage                             [V] 300 300 300      
Rated current                              [A] 30 30 10      
Rated connection capacity (solid/stranded) [AWG] 30~10          
Rated torque                            [Lb. in] 4.43          
General data /          
Screw M3          
Inflammability class UL94 V0          
Ambient temperature                        [”ę] -40~+105          
Relative humidity 5%-95%          
Inspection standard MIL-STD-105E II          
AQL 0.65          
Warranty 12 months          
Material and plating /          
Housing PA66          
Screw Copper alloy£¬Sn plated          
CurrentCarrier Copper alloy£¬Sn plated          
Cage Copper alloy£¬Ni plated          
Wire connecting            
Recommended stripping length 9mm;            
1.For solid wire, stripping wire to the appointed length, then tightening with rated torque.        
2.For stranded wire: stripping wire to the appointed length, mating with corresponding type of ferrule, then tightening with rated torque.
Tightening process should be steady, can’t use explosive force.

DEGSON - DG4 THROUGH-WALL TERMINAL BLOCK

Item Data          
APPROVAL /          
Test standard IEC60998-1          
Pitch                                     [mm] 6.1          
Poles 01P          
IEC60998 Test data  /          
Rated voltage                             [V] 400          
Rated current                              [A] 24          
Rated connection capacity(solid/stranded) [mm²] 0.2~4          
Surge voltage category/pollution degree/material group III/2/I          
Withstanding Voltage                     [KV/min] 2.5          
Rated torque                               [N.m] 1          
UL1059Test data UL 1059          
Use group B C D      
Rated voltage                              [V] 300 / /      
Rated current                         [A] 20 / /      
Rated connection capacity (solid/stranded) [AWG] 30~10          
Rated torque                            [Lb. in] 7.02          
General data /          
Screw M3.5          
Inflammability class UL94 V0          
Ambient temperature                      [”ę] -40~+105          
Relative humidity 5%-95%          
Inspection standard MIL-STD-105E II          
AQL 0.65          
Warranty 12 months          
Material and plating /          
Housing PA66          
Screw Copper alloy£¬Ni plated          
Contact Copper alloy£¬Sn plated          
Cage Copper alloy£¬Ni plated          
Wire connecting            
Recommended stripping length 8mm;            
1.For solid wire, stripping wire to the appointed length, then tightening with rated torque.        
2.For stranded wire: stripping wire to the appointed length, mating with corresponding type of ferrule, then tightening with rated torque.
Tightening process should be steady, can’t use explosive force.

Degson DGV4

Degson DGH95

Degson DGH50

Degson DGH25

Degson DGH16

Degson DGH10

Degson DG4F

Degson DGH4

Degson DG4

 