Visit
Official Website

Mobicon - Remote Electronic Sdn Bhd
19, Jalan PJS 3/59,
Taman Sri Manja,
46000 Petaling Jaya,
Selangor, Malaysia.

+603-7783 2257
+603-7783 4316
+603-7783 4318

Controller (Alarm/Monitor) Selangor, Malaysia, Kuala Lumpur (KL), Petaling Jaya (PJ)

LUTRON TR-RH2W 2 Wires Humidity Transmitter

DESCRIPTION

2 WIRES HUMIDITY TRANSMITTER
Model : TR-RH2W
* Range : 10 %RH to 95 %RH.
* Output : 4 to 20 mA DC, 5.6 mA = 10 %RH, 12 mA = 50 %RH, 16 mA = 75 %RH, 19 mA = 95 %RH
* 2 wires, both for signal and power supply.
* Precision capacitance type humidity sensor.
* External zero and span adjustment.
* Allow high cable load resistance, transmitter can install far away from the controller/incator.
* Protection for the reverse wires connecting.
* TR-RH2W can cooperate the '' 4-20 mA Controller/Alarm/Indicator '' CT-2002-MA, then become a  
 humidity controller and the indicating system. The user can control and monitor the humidity value   
 from far away.

LUTRON TR-PS2W 2 Wire Preassure Transmitter

DESCRIPTION

2 WIRES PRESSURE TRANSMITTER
Model : TR-PS2W-xxBAR
* Range : 2, 5, 10, 20, 50, 100, 400 BAR.
* Output : 4 to 20 mA DC,
 4 mA = 0 pressure,
 20 mA = full scale pressure.
* 2 wires, both for signal and power supply.
* Precision ceramic type pressure sensor.
* External zero and span adjustment.
* Output with socket, easy replacement.
* Allow high cable load resistance, transmitter can install far away from the controller/incator.
* Protection for the reverse wires connecting.
* TR-PS2W can cooperate the ''4-20 mA Controller/Alarm/Indicator'' CT-2012, then become a  
 pressure controller and the indicating system. The user can control and monitor the pressure value  
 from far away.

LUTRON TR-IR420 IR Temperature-TRANSMITTER

DESCRIPTION

4-20 mA output, Infrared Temp.
IR Temp. TRANSMITTER
Model : TR-IR420
* Analog outputs, 4 to 20 mA : 4 mA = 0 oC ( 32 oF ), 20 mA = 300 oC ( 572 oF )
* Emissivity : 0.95, fixed.
* D/S ( Distance/spot ) ratio : 7 : 1.
* Power supply : DC 9V to 30 V : Max. Output Load : 200 ohms.
* 3 wires : Red, bare wire : Power supply Black, bare wire : 4 to 20 mA output.
* Output Temp. ranges : 0 to 300 oC ( 0.053 mA/oC ), 32 to 572 oF ( 0.028 mA/oF ).
* Mounting : Tripod Fix Nut.
* Size : 160 x 92 x 45 mm.

LUTRON PWA-6065 Power Controller/Monitor

DESCRIPTION

POWER CONTROLLER/MONITOR
Model : PWA-6065
* Measurement range (no cooperate with the external CT and the PT).
 Watt : 0 to 6,000 Watt.
 ACV : 0 to 600 ACV, 40 to 400 Hz.
 ACA : 0 to 10 A, 40 to 400 Hz.
* True rms for WATT measurement.
* Current input can cooperate with the external CT (current transformer) such as CT 1000/5A,
 CT 100/5A ...to expend the measurement range. The CT range can be adjusted with default.
* Voltage input can cooperate with the external PT (voltage transformer ) to expend the
 measurement range. The PT range can be adjusted with default.
* Control setting, Hi/Lo alarm setting.
* Control relay output, alarm relay output.
* Power : 90 ACV to 264 ACV, 50/60 Hz.
* RS232/USB computer interface.

LUTRON PVA-6067 Apparent Power Controller/Monitor

DESCRIPTION

APPARENT POWER CONTROLLER/MONITOR
Model : PVA-6067
* Measurement range (no cooperate with the external CT and the PT) :
 VA : 0 to 6,000 VA.
 ACV : 0 to 600 ACV, 40 to 400 Hz.
 ACA : 0 to 10 A, 40 to 400 Hz.
* True rms for VA measurement.
* Current input can cooperate with the external CT (current transformer) such as CT 1000/5A,
 CT 100/5A ...to expend the measurement range. The CT range can be adjusted with default.
* Voltage input can cooperate with the external PT (voltage transformer) to expend the
 measurement range. The PT range can be adjusted with default.
* Control setting, Hi/Lo alarm setting.
* Control relay output, alarm relay output.
* Power : 90 ACV to 264 ACV, 50/60 Hz.
* RS232/USB computer interface.

LUTRON PTM-9957 Temperature Controller/Monitor

DESCRIPTION

TEMPERATURE CONTROLLER/MONITOR
Model : PTM-9957
* Temp. sensor : type K/J/T/E/R/S thermocouple, Pt 100 ohm.
* Type K range : -100 to 1300 oC, oC/oF.
 Type J range : -100 to 1200 oC, oC/oF.
 Type T range : -100 to 400 oC, oC/oF.
 Type E range : -100 to 900 oC, oC/oF.
 Type R range : 0 to 1700 oC, oC/oF.
 Type S range : 0 to 1500 oC, oC/oF.
 Pt 100 ohm range : -199 to 850 oC, oC/oF.
* Resolution : 0.1 degree (< 1000 degree)
 1 degree (≥1000 degree)
* Control setting, Hi/Lo alarm setting.
* Control relay output, alarm relay output.
* Power : 90 ACV to 264 ACV, 50/60 Hz.
* RS-232/USB computer interface.
* DIN size : 96 x 48 mm. Depth : 107 mm.
* Optional type K probe : TP-01, TP-02A, TP-03, TP-04, TP-05.
* Optional Pt probe : TP-100B.
* Optional USB cable, USB-01.
* Optional data acquisition software, SW-U801-WIN, SW-E802.

LUTRON PRS-2321 RS232 Controller/Monitor

DESCRIPTION

RS232 CONTROLLER/MONITOR
Model : PRS-2321
* Cooperate the LUTRON instruments (build in the RS232 interface), the panel meter will show all the
 measuring value.
* U1 control setting, U2 control setting.
* U1 control relay output, U2 control relay output.
* U1, U2, U3 display.
* Power : 90 ACV to 264 ACV, 50/60 Hz.
* RS-232 computer interface.
* Interface cable UPCB-03 is included.
* DIN size : 96 x 48 mm. Depth : 107 mm.

LUTRON PPS-9312 Preassure Controller/Monitor

DESCRIPTION

PRESSURE CONTROLLER/MONITOR
Model : PPS-9312
* Meter connects with 2, 5, 10, 20, 50, 100, 400 bar sensor, no calibration procedures are necessary
 when changing a new sensor .
* Unit select : Bar, PSI, Kg/cm2, inch Hg, mm Hg, inch H2O, meter H2O, Atmosphere.
* Control setting, Hi/Lo alarm setting.
* Control relay output, alarm relay output.
* Power : 90 ACV to 264 ACV, 50/60 Hz.
* Cooperate with the 4-20 mA pressure input, sensor can be installed in the faraway position.
* DC 12V output, used for the power of pressure sensor.
* RS-232/USB computer interface.
* DIN size : 96 x 48 mm. Depth : 107 mm.
* Optional pressure sensor, TR-PS2W-XXBAR.
* Optional USB cable, USB-01.
* Optional data acquisition software, SW-U801-WIN, SW-E802.

LUTRON PPH-2108 PH Controller/Monitor

DESCRIPTION

PH CONTROLLER/MONITOR
Model : PPH-2108
* 0 to 14 pH x 0.01 pH.
* ATC (automatic temperature compensation).
* pH control setting, Temp. control setting.
* pH control relay output, Temp. control relay output.
* Power : 90 ACV to 264 ACV, 50/60 Hz.
* RS-232 computer interface.
* DIN size : 96 x 48 mm. Depth : 107 mm.
* Optional pH electrodes, ATC probe.

LUTRON PPF-6066 Power Factor Controller/Monitor

DESCRIPTION

POWER FACTOR CONTROLLER/MONITOR
Model : PPF-6066
* Power factor Measurement range :
 0.10 to 1.00 PF.
* Resolution : 0.01 PF (power factor).
* Signal input :
 ACV : 0 to 600 ACV, 40 to 400 Hz.
 ACA : 0 to 10 A, 40 to 400 Hz.
* Control setting, Hi/Lo alarm setting.
* Control relay output, alarm relay output.
* Power : 90 ACV to 264 ACV, 50/60 Hz.
* RS232/USB computer interface.

LUTRON PIR-9959A IR TEMPERATURE CONTROLLER/MONITOR

DESCRIPTION

IR Temperature CONTROLLER/MONITOR
Model : PIR-9959A
* Input signal : 4 to 20 mA, 2 wires.
* Input sensor : Infrared Temp. transmitter, TR-IR420.
* Measurement : 0 to 300 oC, oC/oF.
* Control setting, Hi/Lo alarm setting.
* Control relay output, alarm relay output.
* Power : 90 ACV to 260 ACV, 50/60 Hz.
* Use the 4-20 mA input, IR temp. sensor can be installed in the faraway position.
* RS-232/USB computer interface.
* DIN size : 96 x 48 mm. Depth : 107 mm.
* IR Temp. Transmitter, TR-IR420 is the optional accessory.
* Optional USB cable, USB-01.
* Optional data acquisition software,SW-U801-WIN.
* Optional Excel data acquisition software, SW-E802.
 

Recent Updates