19, Jalan PJS 3/59,
Taman Sri Manja,
46000 Petaling Jaya,
Selangor, Malaysia.
+603-7783 4318
25 - 46 of 46 | |||
![]() Lascar Pack of 10 Ambient Pharma Temp & RH Logger EL-CC-2-004 PK10 | ![]() Lascar Wireless Temperature and Humidity Data Logger EL-MOTE-TH | ![]() Lascar WiFi Temperature & Humidity Data Logger EL-WiFi-TH | ![]() Lascar Temperature & Humidity Data Logger with USB EL-USB-2 |
![]() Lascar Temp & RH Logger with Screen and Audible Alarm EL-GFX-2 | ![]() Lascar Temp & RH Data Logger with USB and Display EL-USB-2-LCD | ![]() Lascar Real-time Temperature, Humidity, and Dew-point sensor with USB EL-USB-RT | ![]() Lascar High Accuracy Wireless Temp & RH Data Logger EL-MOTE-TH+Overview· Alarm functions include a built in sounder and LED · Quick, wireless App based configuration · Stores data internally if device loses WiFi connection and automatically uploads it to the Cloud once reconnected · Suitable for indoor and outdoor applications · Industry leading 2 years battery life · Add first logger for free (minimal charges for additional devices) Specification-30 to +80°C -22 to +176°F Typical Temperature Accuracy ±0.2°C ±0.4°F Humidity Measurement Range 0 to 100% RH Humidity Accuracy ±1.8% (20 to 80% RH) ±4% (0 to 100% RH) Battery Life Up to 2 years 4 x 1.5V AA cells Dimensions 93 x 93 x 32mm 3.7 x 3.7 x 1.3' IP Rating 67
|
![]() Lascar High Accuracy WiFi Temp & RH Data Logger EL-WiFi-TH+OverviewEasyLog Cloud gives access to each data logger, and data collected from any internet-enabled device. Change data logger settings remotely, receive email alerts of alarm conditions, link sensors from multiple sites into one account and assign multiple user privileges. The device will store data internally if it loses WiFi connection and automatically uploads it to the Cloud once reconnected. Use the EasyLog Cloud Apps for Android and Apple to easily setup your device and access your data anytime, anywhere. Specification-20 to +60°C / -4 to + 140°F 0 to 100% RH Accuracy ±0.2°C / ±0.4°F ±1.8% RH Typical Readings Unlimited Logging Rate User selectable between 10 seconds and 12 hours Battery Rechargeable Battery / 6 Months Battery Life / Mains Powered Option Calibration Certificate Available Separately Application Info | ![]() Lascar High Accuracy Temp & RH Data Logger with USB EL-USB-2+OverviewSpecificationMeasurement range -35°C to 80°C (-31°F to 176°F) Internal resolution 0.5°C (1°F) Accuracy (overall error) 0.45°C (0.86°F) typical (5 to 60°C) Long term stability <0.02°C (0.04°F) / year Relative Humidity: Measurement range 0 to 100%RH Internal resolution 0.5%RH Accuracy (overall error) 2.05%RH typical (10 to 90%RH) Long term stability <0.25%RH / year Logging Rate User selectable between 10 seconds and 12 hours Battery Life 3 Years | ![]() Lascar High Accuracy Temp & RH Data Logger with Graphic Screen and Audible Alarm EL-GFX-2+OverviewSpecificationMeasurement range -30°C to 80°C (-22°F to 176°F) Internal resolution 0.1°C (0.1°F) Accuracy (overall error) ± 0.25°C (0.41°F) typical (5 to 60°C) Long term stability <0.02°C (0.04°F) / year Relative humidity: Measurement range 0 to 100%RH Internal resolution 0.1%RH Accuracy (overall error) ± 1.85%RH typical (10 to 90%RH) Long term stability <0.25%RH / year Logging rate User selectable between 10 seconds and 1 hour Application Info· Building and Site Monitoring · Housing & Business Premises · Outside Environmental Data | ![]() Lascar High Accuracy Temp & RH Data Logger EL-USB-2-LCD+OverviewSpecificationMeasurement range -35°C to 80°C (-31°F to 176°F) Internal resolution 0.5°C (1°F) Accuracy (overall error) 0.45°C (0.86°F) typical (5 to 60°C) Long term stability <0.02°C (0.04°F) / year Relative Humidity: Measurement range 0 to 100%RH Internal resolution 0.5%RH Accuracy (overall error) 2.05%RH typical (10 to 90%RH) Long term stability <0.25%RH / year Logging Rate User selectable between 10 seconds and 12 hours Battery Life 2 Years Calibration Certificate Available Separately Application Info· Facilities Management · Housing & Business Premises · Outside Environmental Data · Agriculture & Animal Welfare · Veterinary · Museums & Exhibitions |
![]() Lascar High Accuracy 21CFR WiFi Temp & RH Data Logger EL- WiFi-21CFR-TH+OverviewThe device will store data internally if it loses WiFi connection and automatically uploads it to the Cloud once reconnected. Why buy a 21CFR logger? The 21 CFR Part 11 regulations issued by the US Food and Drug Administration (FDA) give the criteria under which electronic records can be considered by the FDA as equivalent to paper records. If you need to meet these regulations or have enhanced data security requirements then you should choose one of our 21CFR loggers, otherwise our standard loggers will suffice. Learn more about 21 CFR Part 11. 21CFR Cloud subscription delivers all of the flexibility of remote monitoring and can be installed as part of a 21CFR compliant system. Features include permission-based use, authority level sign-off and full system audit to ensure data monitored and collected is regulated to 21CFR Part 11 standard. This device requires a subscription to our EasyLog 21CFR Cloud service. Specification-20 to +60°C / -4 to + 140°F 0 to 100% RH Accuracy ±0.2°C / ±0.4°F ±1.8% RH Typical Readings Unlimited Logging Rate User selectable between 10 seconds and 12 hours Battery Life 6 Months Calibration Certificate Available Separately Application Info | ![]() Lascar Dual Channel Temp, RH & Dew Point Data Logger with External Probe EL-GFX-D2OverviewIts high contrast, dot-matrix LCD with three face-buttons for navigation gives real-time trend analysis, data summaries and the ability to start, stop and restart the data logger without connecting to a PC. EasyLog USB software enables quick configuration and data download via the USB port. Supplied with two lithium batteries, which can typically allow logging for up to 1 year. It can also be powered from USB. · Logging rates between 10 seconds and 1 hour · Stores over 250,000 readings per channel for temperature and humidity · User triggered logging mode · Up to two channels supported (supplied with one probe)
*only one probe is included with the device.
SpecificationMeasurement Range -30 to +80ºC (-22 to +176ºF) Accuracy (overall error) ±0.3ºC (±0.6ºF) typical Resolution 0.1ºC (0.2ºF) Relative Humidity: Measurement Range 0 to 100%RH Accuracy (overall error) ±2.05%RH typical (20 to 80%RH) Resolution ±0.1%RH Dew Point Accuracy ±1.1ºC (±2.0ºF) typical Probe Cable Length 2m (only one probe supplied) Battery Life 1 year
| ![]() Lascar All Lascar Data Logger Temperature & Humidity | ![]() Lascar 21CFR WiFi Temp & RH Data Logger EL-WiFi-21CFR-THOverviewThe device will store data internally if it loses WiFi connection and automatically uploads it to the Cloud once reconnected. Why buy a 21CFR logger? The 21 CFR Part 11 regulations issued by the US Food and Drug Administration (FDA) give the criteria under which electronic records can be considered by the FDA as equivalent to paper records. If you need to meet these regulations or have enhanced data security requirements then you should choose one of our 21CFR loggers, otherwise our standard loggers will suffice. Learn more about 21 CFR Part 11. 21CFR Cloud subscription delivers all of the flexibility of remote monitoring and can be installed as part of a 21CFR compliant system. Features include permission-based use, authority level sign-off and full system audit to ensure data monitored and collected is regulated to 21CFR Part 11 standard. This device requires a subscription to our EasyLog 21CFR Cloud service. Specification-20 to +60°C / -4 to + 140°F 0 to 100% RH Accuracy ±0.3°C / ±0.6°F ±2.5% RH Typical Readings Unlimited Logging Rate User selectable between 10 seconds and 12 hours Battery Life 6 Months Calibration Certificate Available Separately Application Info· Veterinary · Chilling, Freezing & Storing Food · Facilities Management |
![]() Lascar 21CFR Temperature and Humidity Data Logger with USB and LCD EL-21CFR-2-LCDOverviewWhy buy a 21CFR logger? The 21 CFR Part 11 regulations issued by the US Food and Drug Administration (FDA) give the criteria under which electronic records can be considered by the FDA as equivalent to paper records. If you need to meet these regulations or have enhanced data security requirements then you should choose one of our 21CFR loggers, otherwise our standard loggers will suffice. Learn more about 21 CFR Part 11. Used in conjunction with Lascar's 21CFR Part 11 software, the logger enjoys all of the core offerings of the original EasyLog software, but with additional 21CFR characteristics including user permissions, encrypted data which cannot be edited, full audit trail and electronic signatures for all activity. Easily set up the logger and view downloaded data by plugging the unit into a PC’s USB port and using the free 21CFR Part 11 software provided. Supplied with ½ AA battery and wall mount clip. SpecificationMeasurement range -35°C to 80°C (-31°F to 176°F) Internal resolution 0.5°C (1°F) Accuracy (overall error) 0.55°C (1.04°F) typical (5 to 60°C) Long term stability <0.02°C (0.04°F) / year Relative Humidity: Measurement range 0 to 100%RH Internal resolution 0.5%RH Accuracy (overall error) 2.25%RH typical (20 to 80%RH) Long term stability <0.25%RH / year Logging Rate User selectable between 10 seconds and 12 hours Battery Life 2 Years Calibration Certificate Available Separately Application Info · Vaccine Storage · Cold Chain in the Pharma Industry · Blood & Blood Component Storage | ![]() Lascar 21CFR High Accuracy Temp & RH Data Logger EL-21CFR-2-LCD+OverviewWhy buy a 21CFR logger? The 21 CFR Part 11 regulations issued by the US Food and Drug Administration (FDA) give the criteria under which electronic records can be considered by the FDA as equivalent to paper records. If you need to meet these regulations or have enhanced data security requirements then you should choose one of our 21CFR loggers, otherwise our standard loggers will suffice. Learn more about 21 CFR Part 11. Used in conjunction with Lascar's 21CFR Part 11 software, the logger enjoys all of the core offerings of the original EasyLog software, but with additional 21CFR characteristics including user permissions, encrypted data which cannot be edited, full audit trail and electronic signatures for all activity. Easily set up the logger and view downloaded data by plugging the unit into a PC’s USB port and using the free 21CFR Part 11 software provided. Supplied with ½ AA battery and wall mount clip. SpecificationMeasurement range -35°C to 80°C (-31°F to 176°F) Internal resolution 0.5°C (1°F) Accuracy (overall error) 0.45°C (0.86°F) typical (5 to 60°C) Long term stability <0.02°C (0.04°F) / year Relative Humidity: Measurement range 0 to 100%RH Internal resolution 0.5%RH Accuracy (overall error) 2.05%RH typical (10 to 90%RH) Long term stability <0.25%RH/year Logging rate User selectable between 10 seconds & 12 hours Battery life 2 years (at 25°C and 1 minute logging rate, LCD on) Calibration Certificate Available Separately
| ![]() Lascar Voltage Data Logger with USB EL-USB-3Overview
This standalone data logger measures more than 32,000 readings over a 0 to 30V d.c. range at a resolution of 50 mV d.c. The data logger is supplied with a 0 to 30V d.c. cap featuring a pair of screw terminals and measurement leads terminating in crocodile clips. Easily set up the logger and view downloaded data by plugging the unit into a PC’s USB port and using the free EasyLog software provided. Data can then be graphed, printed and exported to other applications for detailed analysis. Supplied with ½ AA battery and wall mount clip. Specification
Measurement Range
0 to 30V d.c.
Accuracy
±1%
Readings
32,510
Logging Rate
User selectable between 1 second and 12 hours
Battery Life
3 Years
| ![]() Lascar OEM Packaged Voltage Data Logger EL-OEM-3OverviewSpecification2.75 to 3.6V d.c. Supply Current 0.01 to 3mA Measurement Range 0 to 2.4V d.c. Accuracy (overall error) ±1% Readings 64,000 Logging Rate User selectable between 1 second and 12 hours Operating temperature -40 to 85°C (-40 to 185°F) Application Info· Integration into existing designs · Precision instrumentation systems · Power supply monitoring · Hand held instruments · Industrial process monitoring |
![]() Lascar Current Data Logger with USB EL-USB-4This standalone data logger can take more than 16,000 readings over a -35 to +80°C (-31 to +176°F) measurement range. Easily set up the logger and view downloaded data by plugging the unit into a PC’s USB port and using the free EasyLog software provided. Data can then be graphed, printed and exported to other applications for detailed analysis. Supplied with ½ AA battery and wall mount clip. Calibration certificate available to purchase separately. Specification
Measurement Range
-35 to +80°C / -31 to + 176°F
Accuracy (overall error)
+/- 0.5°C typical
Readings
16,382
Logging Rate
User selectable between 10 seconds and 12 hours
Application InfoThe EL-USB-1 is suitable for a wide variety of applications. These include:
| ![]() Lascar AC and DC Millivolt Data Logger EL-USB-ACT | ||
25 - 46 of 46 |