Visit
Official Website

Mobicon - Remote Electronic Sdn Bhd
19, Jalan PJS 3/59,
Taman Sri Manja,
46000 Petaling Jaya,
Selangor, Malaysia.

+603-7783 2257
+603-7783 4316
+603-7783 4318

Din Rail Terminal Block Selangor, Malaysia, Kuala Lumpur (KL), Petaling Jaya (PJ)

1 - 24 of 403
|<1 2 3 4 5 6 7 8 9 10 >|

DEGSON EEA16 DIN RAIL TERMINAL BLOCK

Item Data    
Test standard /    
Pitch                                              [mm] 12    
Poles 1-May    
EN61984 Test data /    
Rated voltage                                         [V] /    
Rated current                                         [A] /    
Rated connection capacity(solid/stranded)             [mm²] /    
Surge voltage category/pollution degree/material group /    
Rated impulse voltage                                [KV] /    
Rated torque                                        [N.m] /    
UL1059Test data /    
Use group B C D
Rated voltage                                       [V] / / /
Rated current                                         [A] / / /
Rated connection capacity (solid/stranded)           [AWG] /    
Rated torque                                       [Lb.   in] /    
General data /    
Stripping length                                      [mm] /    
Screw /    
Inflammability class UL94 V-0    
Ambient temperature                                  [¡æ] -40~+105    
Relative humidity 5%-95%    
Inspection standard MIL-STD-105E   II    
AQL 0.65    
Warranty 12   months    
Material and plating /    
Housing PA66

DEGSON EEA10 DIN RAIL TERMINAL BLOCK

Item Data    
Test standard /    
Pitch                                              [mm] 10    
Poles 1-May    
EN61984 Test data /    
Rated voltage                                         [V] /    
Rated current                                         [A] /    
Rated connection capacity(solid/stranded)             [mm²] /    
Surge voltage category/pollution degree/material group /    
Rated impulse voltage                                [KV] /    
Rated torque                                        [N.m] /    
UL1059Test data /    
Use group B C D
Rated voltage                                       [V] / / /
Rated current                                         [A] / / /
Rated connection capacity (solid/stranded)           [AWG] /    
Rated torque                                       [Lb.   in] /    
General data /    
Stripping length                                      [mm] /    
Screw /    
Inflammability class UL94 V-0    
Ambient temperature                                  [¡æ] -40~+105    
Relative humidity 5%-95%    
Inspection standard MIL-STD-105E   II    
AQL 0.65    
Warranty 12   months    
Material and plating /    
Housing PA66

DEGSON EEA6 DIN RAIL TERMINAL BLOCK

Item Data    
Test standard /    
Pitch                                              [mm] 8    
Poles 1-May    
EN61984 Test data /    
Rated voltage                                         [V] /    
Rated current                                         [A] /    
Rated connection capacity(solid/stranded)             [mm²] /    
Surge voltage category/pollution degree/material group /    
Rated impulse voltage                                [KV] /    
Rated torque                                        [N.m] /    
UL1059Test data /    
Use group B C D
Rated voltage                                       [V] / / /
Rated current                                         [A] / / /
Rated connection capacity (solid/stranded)           [AWG] /    
Rated torque                                       [Lb.   in] /    
General data /    
Stripping length                                      [mm] /    
Screw /    
Inflammability class UL94 V-0    
Ambient temperature                                  [¡æ] -40~+105    
Relative humidity 5%-95%    
Inspection standard MIL-STD-105E   II    
AQL 0.65    
Warranty 12   months    
Material and plating /    
Housing PA66

DEGSON EEA4 DIN RAIL TERMINAL BLOCK

Item Data    
Test standard /    
Pitch                                              [mm] 6.1    
Poles 1-May    
EN61984 Test data /    
Rated voltage                                         [V] /    
Rated current                                         [A] /    
Rated connection capacity(solid/stranded)             [mm²] /    
Surge voltage category/pollution degree/material group /    
Rated impulse voltage                                [KV] /    
Rated torque                                        [N.m] /    
UL1059Test data /    
Use group B C D
Rated voltage                                       [V] / / /
Rated current                                         [A] / / /
Rated connection capacity (solid/stranded)           [AWG] /    
Rated torque                                       [Lb.   in] /    
General data /    
Stripping length                                      [mm] /    
Screw /    
Inflammability class UL94 V-0    
Ambient temperature                                  [¡æ] -40~+105    
Relative humidity 5%-95%    
Inspection standard MIL-STD-105E   II    
AQL 0.65    
Warranty 12   months    
Material and plating /    
Housing PA66    
 

DEGSON EEA2.5 DIN RAIL TERMINAL BLOCK

Item Data    
Test standard /    
Pitch                                              [mm] 5    
Poles 1-May    
EN61984 Test data /    
Rated voltage                                         [V] /    
Rated current                                         [A] /    
Rated connection capacity(solid/stranded)             [mm²] /    
Surge voltage category/pollution degree/material group /    
Rated impulse voltage                                [KV] /    
Rated torque                                        [N.m] /    
UL1059Test data /    
Use group B C D
Rated voltage                                       [V] / / /
Rated current                                         [A] / / /
Rated connection capacity (solid/stranded)           [AWG] /    
Rated torque                                       [Lb.   in] /    
General data /    
Stripping length                                      [mm] /    
Screw /    
Inflammability class UL94 V-0    
Ambient temperature                                  [¡æ] -40~+105    
Relative humidity 5%-95%    
Inspection standard MIL-STD-105E   II    
AQL 0.65    
Warranty 12   months    
Material and plating /    
Housing PA66

DEGSON EEA1.5 DIN RAIL TERMINAL BLOCK

Item Data    
Test standard /    
Pitch                                              [mm] 4    
Poles 1-May    
EN61984 Test data /    
Rated voltage                                         [V] /    
Rated current                                         [A] /    
Rated connection capacity(solid/stranded)             [mm²] /    
Surge voltage category/pollution degree/material group /    
Rated impulse voltage                                [KV] /    
Rated torque                                        [N.m] /    
UL1059Test data /    
Use group B C D
Rated voltage                                       [V] / / /
Rated current                                         [A] / / /
Rated connection capacity (solid/stranded)           [AWG] /    
Rated torque                                       [Lb.   in] /    
General data /    
Stripping length                                      [mm] /    
Screw /    
Inflammability class UL94 V-0    
Ambient temperature                                  [¡æ] -40~+105    
Relative humidity 5%-95%    
Inspection standard MIL-STD-105E   II    
AQL 0.65    
Warranty 12   months    
Material and plating /    
Housing PA66

DEGSON DS2.5K6 DIN RAIL TERMINAL BLOCK

Item Data    
APPROVAL /    
Test standard IEC61984£ºUL1059    
Pitch                                               [mm] 6.5    
Poles 06P    
IEC61984 Test data /    
Rated voltage                                         [V] 320    
Rated current                                       [A] 24    
Rated connection capacity (solid/stranded)            [mm2] 0.75-2.5    
(Surge voltage category/pollution degree/material group) III/3/I    
Rated impulse voltage                               [KV] 4    
Rated torque                                         [N·m] /    
UL1059Test data UL   File Number E228872    
Use group B C D
Rated voltage                                      [V] 300 / 300
Rated current                                      [A] 15 / 10
Rated connection capacity (solid/stranded)            [AWG] 18-14    
Rated torque                                      [Lb. in] /    
General data /    
Screw    
Inflammability class                                UL94 V-0    
Ambient temperature                               [¡æ] -40~+105    
Relative humidity 5%-95%    
Inspection standard MIL-STD-105E   II    
AQL 0.65    
Warranty 12   months    
Material and plating /    
Housing PA66    
Contact Copper alloy£¬Sn plated    
Recommended stripping length 7-8mm;

DEGSON WFC2.5-8 DIN RAIL TERMINAL BLOCK

Item Data
APPROVAL /
Test   standard /
Pitch                                      [mm] 34.8
Poles 01P
Inflammability   classUL94 V-0
Ambient   temperature                        [¡æ] -40~+105
Relative   humidity 5%-95%
Inspection   standard MIL-STD-105E   II
AQL 0.65
Warranty 12   months
Material   and plating /
Housing PA66
Contact Copper£¬Tin plated

DEGSON WFC2.5-7 DIN RAIL TERMINAL BLOCK

Item Data
APPROVAL /
Test   standard /
Pitch                                      [mm] 29.8
Poles 01P
Inflammability   classUL94 V-0
Ambient   temperature                        [¡æ] -40~+105
Relative   humidity 5%-95%
Inspection   standard MIL-STD-105E   II
AQL 0.65
Warranty 12   months
Material   and plating /
Housing PA66
Contact Copper£¬Tin plated

DEGSON WFC2.5-6 DIN RAIL TERMINAL BLOCK

Item Data
APPROVAL /
Test   standard /
Pitch                                      [mm] 24.8
Poles 01P
Inflammability   classUL94 V-0
Ambient   temperature                        [¡æ] -40~+105
Relative   humidity 5%-95%
Inspection   standard MIL-STD-105E   II
AQL 0.65
Warranty 12   months
Material   and plating /
Housing PA66

DEGSON WFC2.5-5 DIN RAIL TERMINAL BLOCK

 
Item Data
APPROVAL /
Test   standard /
Pitch                                      [mm] 19.8
Poles 01P
Inflammability   classUL94 V-0
Ambient   temperature                        [¡æ] -40~+105
Relative   humidity 5%-95%
Inspection   standard MIL-STD-105E   II
AQL 0.65
Warranty 12   months
Material   and plating /
Housing PA66
Contact Copper£¬Tin plated

DEGSON PC50-PE DIN RAIL TERMINAL BLOCK

Item Data    
APPROVAL      
 
/    
Test standard IEC/EN60947-7-2£º2009 / UL1059    
Pitch                                    [mm] 20    
Poles 01P    
EN61984 Test data /    
Rated voltage                              [V] /    
Rated current                             [A] /    
Rated connection capacity(solid/stranded) [mm²] 16-50    
Surge voltage category/pollution degree/material group III/3/I    
Rated impulse voltage                   [KV] 8    
Rated torque                              [N.m] 6    
UL1059Test data /    
Use group B C D
Rated voltage                             [V] / / /
Rated current                            [A] / / /
Rated connection capacity (solid/stranded) [AWG] 6/1/2000    
Rated torque                           [Lb. in] 52.17    
General data /    
Screw M6    
Inflammability class UL94 V-0    
Ambient temperature                      [¡æ] -40~+105    
Relative humidity 5%-95%    
Inspection standard MIL-STD-105E II    
AQL 0.65    
Warranty 12 months    
Material and plating /    
Housing PA66    
Screws Copper alloy£¬Zn plated    
Contact Copper alloy£¬Tin plated    
Cage Copper alloy£¬Zn plated    
Wire connecting      
Recommended stripping length23-24mm;      
For solid wire, stripping wire to the appointed length, then tightening with rated torque.    
For stranded wire: stripping wire to the appointed length, mating with corresponding type of ferrule, then tightening with rated torque.
Tightening process should be steady, can’t use explosive force.  

DEGSON PC35-PE DIN RAIL TERMINAL BLOCK

Item Data    
APPROVAL      
 
/
   
Test standard IEC/EN60947-7-2£º2009 / UL1059    
Pitch                                     [mm] 15.2    
Poles 01P    
EN60947 Test data /    
Rated voltage                              [V] /    
Rated current                              [A] /    
Rated connection capacity(solid/stranded) [mm²] 35    
Surge voltage category/pollution degree/material group III/3/I    
Rated impulse voltage                   [KV] 8    
Rated torque                              [N.m] 2.5    
UL1059Test data /    
Use group B C D
Rated voltage                            [V] / / /
Rated current                              [A] / / /
Rated connection capacity (solid/stranded) [AWG] 18-0    
Rated torque                           [Lb. in] 22.15    
General data /    
Screw M6    
Inflammability class UL94 V-0    
Ambient temperature                        [¡æ] -40~+105    
Relative humidity 5%-95%    
Inspection standard MIL-STD-105E II    
AQL 0.65    
Warranty 12 months    
Material and plating /    
Housing PA66    
Screws Copper alloy£¬Ni plated    
Contact Copper alloy£¬Ni plated    
Cage Copper alloy£¬Ni plated    
Wire connecting      
Recommended stripping length14-15mm;      
For solid wire, stripping wire to the appointed length, then tightening with rated torque.    
For stranded wire: stripping wire to the appointed length, mating with corresponding type of ferrule, then tightening with rated torque.
Tightening process should be steady, can’t use explosive force.  

DEGSON PC16-PE DIN RAIL TERMINAL BLOCK

Item Data    
APPROVAL    
Test standard IEC/EN60947-7-2£º2009 / UL1059    
Pitch                                    [mm] 12.2    
Poles 01P    
EN60947 Test data VDE certificate NO. 40024858    
Rated voltage                              [V] /    
Rated current                             [A] /    
Rated connection capacity(solid/stranded) [mm²] 0.2-16    
Surge voltage category/pollution degree/material group III/3/I    
Rated impulse voltage                   [KV] 8    
Rated torque                               [N.m] 1.2    
UL1059Test data UL File Number E228872    
Use group B C D
Rated voltage                             [V] / / /
Rated current                              [A] / / /
Rated connection capacity (solid/stranded) [AWG] 12-Apr    
Rated torque                            [Lb. in] 10.53    
General data /    
Screw M4    
Inflammability class UL94 V-0    
Ambient temperature                       [¡æ] -40~+105    
Relative humidity 5%-95%    
Inspection standard MIL-STD-105E II    
AQL 0.65    
Warranty 12 months    
Material and plating /    
Housing PA66    
Screws Copper alloy£¬Ni plated    
Contact Copper alloy£¬Ni plated    
Cage Copper alloy£¬Ni plated    
Wire connecting      
Recommended stripping length 10-11mm;      
For solid wire, stripping wire to the appointed length, then tightening with rated torque.    
For stranded wire: stripping wire to the appointed length, mating with corresponding type of ferrule, then tightening with rated torque.
Tightening process should be steady, can’t use explosive force.  

DEGSON PC10-PE DIN RAIL TERMINAL BLOCK

Item Data    

APPROVAL
     
Test standard IEC/EN60947-7-2£º2009 / UL1059    
Pitch                                     [mm] 10.2    
Poles 01P    
EN60947 Test data   VDE certificate NO. 40024757    
Rated voltage                            [V] /    
Rated current                              [A] /    
Rated connection capacity(solid/stranded) [mm²] 0.2-10    
Surge voltage category/pollution degree/material group III/3/I    
Rated impulse voltage                    [KV] 8    
Rated torque                              [N.m] 1.2    
UL1059Test data UL File Number E228872    
Use group B C D
Rated voltage                             [V] / / /
Rated current                             [A] / / /
Rated connection capacity (solid/stranded) [AWG] 24-Jun    
Rated torque                            [Lb. in] 10.53    
General data /    
Screw M4    
Inflammability class UL94 V-0    
Ambient temperature                       [¡æ] -40~+105    
Relative humidity 5%-95%    
Inspection standard MIL-STD-105E II    
AQL 0.65    
Warranty 12 months    
Material and plating /    
Housing PA66    
Screws Copper alloy£¬Ni plated    
Contact Copper alloy£¬Tin plated    
Cage Copper alloy£¬Ni plated    
Wire connecting      
Recommended stripping length 9-10mm;      
For solid wire, stripping wire to the appointed length, then tightening with rated torque.    
For stranded wire: stripping wire to the appointed length, mating with corresponding type of ferrule, then tightening with rated torque.
Tightening process should be steady, can’t use explosive force.  

DEGSON PC6-PE DIN RAIL TERMINAL BLOCK

Item Data    
APPROVAL
     
Test standard IEC/EN60947-7-2£º2009 / UL1059    
Pitch                                     [mm] 8.2    
Poles 01P    
EN60947 Test data VDE certificate NO. 40024758    
Rated voltage                            [V] /    
Rated current                            [A] /    
Rated connection capacity(solid/stranded) [mm²] 0.2-6.0    
Surge voltage category/pollution degree/material group III/3/I    
Rated impulse voltage                    [KV] 8    
Rated torque                               [N.m] 1.2    
UL1059Test data UL File Number E228872    
Use group B C D
Rated voltage                              [V] / / /
Rated current                             [A] / / /
Rated connection capacity (solid/stranded) [AWG] 24-Oct    
Rated torque                            [Lb. in] 10.53    
General data /    
Screw M4    
Inflammability class UL94 V-0    
Ambient temperature                       [¡æ] -40~+105    
Relative humidity 5%-95%    
Inspection standard MIL-STD-105E II    
AQL 0.65    
Warranty 12 months    
Material and plating /    
Housing PA66    
Screws Copper alloy£¬Ni plated    
Contact Copper alloy£¬Tin plated    
Cage Copper alloy£¬Ni plated    
Wire connecting      
Recommended stripping length 9-10mm;      
For solid wire, stripping wire to the appointed length, then tightening with rated torque.    
For stranded wire: stripping wire to the appointed length, mating with corresponding type of ferrule, then tightening with rated torque.
Tightening process should be steady, can’t use explosive force.

DEGSON DG100-20A BARRIER TERMINAL BLOCK

Item Data    
APPROVAL /    
Test standard UL1059    
Pitch                                     [mm] 25    
UL1059Test data UL1059    
Poles 01~16P    
Use group B C D
Rated voltage                             [V] 600 / /
Rated current                              [A] 101 / /
Rated connection capacity(solid/stranded) [AWG] 20~2    
Rated torque                  [Lb. in] 60    
General data /    
Screw M8    
Inflammability class UL94 V-0    
Ambient temperature                        [¡æ] -40~+125    
Relative humidity 5%-95%    
Inspection standard MIL-STD-105E II    
AQL 0.65    
Warranty 12 months    
Material and plating /    
Housing PC    
Screws Steel£¬ Zn plated    
Contact Copper alloy£¬Ni plated    
Wire connecting      
For stranded wire: stripping wire to the appointed length, mating with corresponding type of ferrule, then tightening with rated torque.
Tightening process should be steady, can’t use explosive force.  

DEGSON WS2.5 SPRING-CAGE TYPE DIN RAIL TERMINAL BLOCK

WS2.5-11030000092

spring-cage type Din-Rail TB£¬ Rated voltage: 800 V£¬Rated current: 24 A£¬ connection method: Spring-cage/plug-in connection£¬ number of connections: 2£¬ Number of potentials: 1£¬ cross section: 0.2 mm² - 2.5 mm²£¬ AWG: 28 - 14£¬ width: 5 mm£¬ height: 32.45mm£¬ Color: gray£¬ mounting type: NS 35/7,5£¬ NS 35/15

DEGSON WS1.5T-DB-11A(H) SPRING-CAGE TYPE DIN RAIL TERMINAL BLOCK

WS1.5T-DB-11A(H)-11030000393

spring-cage type Din-Rail TB£¬ Rated voltage: 800 V£¬Rated current: 17.5 A£¬ connection method: Spring-cage/plug-in connection£¬ number of connections: 4£¬ Number of potentials: 1£¬ cross section: 0.2 mm² - 1.5 mm²£¬ AWG: 28 - 16£¬ width: 8 mm£¬ height: 17mm£¬ Color: gray£¬ mounting type: NS 35/7,5£¬ NS 35/15

DEGSON DS1.5 DIN RAIL TERMINAL BLOCK

DS1.5-11040000010

Push-in Din-Rail TB£¬ Rated voltage: 500 V£¬Rated current: 17.5 A£¬ connection method: Push-in connection£¬ number of connections: 2£¬ Number of potentials: 1£¬ cross section: 0.14 mm² - 1.5 mm²£¬ AWG: 26 - 14£¬ width: 3.5 mm£¬ height: 30.6 mm£¬ Color: gray£¬ mounting type: NS 35/7,5£¬ NS 35/15

DEGSON - WS2.5T-DIN35 DIN RAIL TERMINAL BLOCK

 Item Data    
APPROVAL      
Test   standard IEC60947-7-1£ºUL1059    
Pitch                                                [mm] 10    
Poles 01P    
IEC60947-7-1   Test data  /    
Rated   voltage                                          [V] 800    
Rated   current                                          [A] 24    
Rated   connection capacity (solid/stranded)             [mm²] 0.2-2.5    
Surge   voltage category/pollution degree/material group III/3/I    
Rated   impulse voltage                                 [KV] 8    
Rated   torque                                         [N.m] /    
UL1059Test   data UL   File Number E228872    
Use   group B C D
Rated   voltage                                          [V] 600 600 600
Rated   current                                          [A] 20 20 5
Rated   connection capacity(solid/stranded)              [AWG] 28-Dec    
Rated   torque                                       [Lb. in] /    
General   data /    
Screw /    
Inflammability   classUL94 V-0    
Ambient   temperature                                   [¡æ] -40~+105    
Relative   humidity 5%-95%    
Inspection   standard MIL-STD-105E   II    
AQL 0.65    
Warranty 12   months    
Material   and plating /    
Housing PA66    
Spring Stainless      
Current   carrier Copper£¬Sn plated    
Wire   connecting      
Recommended   stripping length 8-9mm;      
1.£©For solid wire, stripping wire to the appointed length, with   Screw driver down connection.  
2.£©For stranded wire: stripping wire to the appointed length,    with Screw driver down connection.  
 

DEGSON - WS2.5-DIN35 DIN RAIL TERMINAL BLOCK

Item Data    
APPROVAL /    
Test standard IEC60947-7-1£º2009 / UL1059    
Pitch                                   [mm] 6    
Poles 01P    
EN60947 -7-1Test data)    /    
Rated voltage                             [V] 800    
Rated current                             [A] 24    
Rated connection   capacity)(solid/stranded)[mm²] 0.2~2.5    
Surge   voltage category/pollution degree/material group III/3/I    
Rated impulse   voltage                  [KV] 8    
Rated torque                              [N.m] /    
UL1059Test data /    
Use group B C D
Rated voltage                              [V] 600 / /
Rated current                             [A] 15 / /
Rated connection   capacity) (solid/stranded [AWG] 28-Dec    
Rated torque                              [Lb. in] /    
General data /    
Screw /    
Inflammability class   UL94 V-0    
Ambient   temperature                       [¡æ] -40~+105    
Relative humidity 5%-95%    
Inspection standard MIL-STD-105E   II    
(AQL 0.65    
Warranty 12   months    
Material and plating /    
Housing PA66    
Spring  Stainless    
Current carrier Copper alloy£¬Sn plated    
 Wire connecting      
8-9mm; Recommended stripping   length 8-9mm;      
1.£©For solid   wire, stripping wire to the appointed length, with Screw driver down   connection.  
2.£©For stranded   wire: stripping wire to the appointed length,    with Screw driver down connection.
Tightening   process should be steady, can’t use explosive force.)

DEGSON - WS2.5-DIN15 DIN RAIL TERMINAL BLOCK

Item Data    
APPROVAL      
Test standard IEC60947-7-1£º2009 / UL1059    
Pitch                                      [mm] 6    
Poles 01P    
EN60947-7-1 Test data    /    
Rated voltage                              [V] 800    
Rated current                              [A] 24    
Rated connection   capacity(solid/stranded) [mm²] 0.2~2.5    
Surge   voltage category/pollution degree/material group III/3/I    
Rated impulse   voltage                    [KV] 8    
Rated torque                               [N.m] /    
UL1059Test data UL   File Number E228872    
Use group B C D
Rated voltage                              [V] 600 600 600
Rated current                              [A] 20 20 5
Rated connection   capacity (solid/stranded) [AWG] 28-Dec    
Rated torque                              [Lb. in] /    
General data /    
Screw /    
Inflammability class   UL94 V-0    
Ambient   temperature                        [¡æ] -40~+105    
Relative humidity 5%-95%    
Inspection standard MIL-STD-105E   II    
AQL 0.65    
Warranty 12   months    
Material and plating /    
Housing PA66    
Spring Stainless    
Current carrier
Copper alloy£¬Sn plated
   
Wire connecting      
Recommended stripping   length 8-9mm;      
For solid   wire, stripping wire to the appointed length, with Screw driver down   connection.    
For stranded   wire: stripping wire to the appointed length,    with Screw driver down connection.  
Tightening   process should be steady, can’t use explosive force.

DEGSON - WS2.5T-DIN15 DIN RAIL TERMINAL BLOCK

 Item Data    
APPROVAL      
Test   standard IEC60947-7-1£ºUL1059    
Pitch                                                [mm] 10    
Poles 01P    
IEC60947-7-1   Test data  /    
Rated   voltage                                          [V] 800    
Rated   current                                          [A] 24    
Rated   connection capacity (solid/stranded)             [mm²] 0.2-2.5    
Surge   voltage category/pollution degree/material group III/3/I    
Rated   impulse voltage                                 [KV] 8    
Rated   torque                                         [N.m] /    
UL1059Test   data UL   File Number E228872    
Use   group B C D
Rated   voltage                                          [V] 600 600 600
Rated   current                                          [A] 20 20 5
Rated   connection capacity(solid/stranded)              [AWG] 28-Dec    
Rated   torque                                       [Lb. in] /    
General   data /    
Screw /    
Inflammability   classUL94 V-0    
Ambient   temperature                                   [¡æ] -40~+105    
Relative   humidity 5%-95%    
Inspection   standard MIL-STD-105E   II    
AQL 0.65    
Warranty 12   months    
Material   and plating /    
Housing PA66    
Spring Stainless      
Current   carrier Copper£¬Sn plated    
Wire   connecting      
Recommended   stripping length 8-9mm;      
1.£©For solid wire, stripping wire to the appointed length, with   Screw driver down connection.  
2.£©For stranded wire: stripping wire to the appointed length,    with Screw driver down connection.

1 - 24 of 403
|<1 2 3 4 5 6 7 8 9 10 >|

Recent Updates